Abstract

Purpose. The contradictions in the use of the term «reactive power» require justification by clarifying its physical meaning. The aim of the paper is to reveal the physical meaning of the term «reactive power» applied to three-phase three-wire and four-wire energy supply systems. Methodology. We have applied the modern theory of instantaneous active and reactive power, the graphical filling complex branched energy supply system of simplified design scheme, the theory of electrical circuits, computer Matlab-simulation. Results. We have provided answers to six basic questions that reveal the physical meaning and definition of the concept of «reactive power». We have justified the assumptions suggesting a universal calculation formula to determine the relative total power loss in the three-phase energy supply system as the sum of four components caused by: a minimal losses, reactive power, active power pulsations and instantaneous current flow in the neutral wire. Originality. We have developed the definition that reveals the physical meaning of the term «reactive power» for three-phase energy supply systems corresponding to modern theories of instantaneous active and reactive power. Practical value. We have proposed energy efficiency method ideas of energy supply systems with non-linear load based on the additional components of the power losses calculation. The further development of the method will allow to amend the design, selection and operation of the power active filters practices.

Authors and Affiliations

G. G. Zhemerov, D. V. Tugay

Keywords

Related Articles

CLASS STRUCTURE OF ELECTROMECHANICAL ENERGY CONVERTER MODELS WITH UML-DIAGRAMS APPLICATION

Theoretical results are presented, mathematical model formation by means of inheritance from a generalized class template is shown for a general electromechanical energy converter.

COMPARATIVE ANALYSIS OF ACTIVE POWER LOSSES OF INDUCTION MOTORS WITH CYLINDRICAL AND AXIAL AIR GAPS

Purpose. To find the analytical expressions of determining the optimum geometric dimensions by criteria of the losses minimum of axial field squirrel-cage induction motors and to compare traditional and axial field motor...

RESEARCH OF THE APPLICATIONS POSSIBILITY OF INTERFACE RELAY IN HYBRID SWITCHING SYSTEMS OF BISTABLE ACTUATORS WINDINGS

Purpose. Development of methods of experimental determination of action coordination characteristics of semiconductor and mechanical switching elements in systems of hybrid commutation of bistable actuators coils taking...

MASS AND COST FIGURES FOR SPATIAL AXIAL THREE-PHASE ELECTROMAGNETIC SYSTEMS WITH CIRCULAR AND HEXAGONAL FORMING CONTOURS OF TWISTED MAGNETIC CORE RODS

For a spatial three-phase axial electromagnetic system with double-contour phase elements of the twisted butt-end magnetic core, analytical dependences for optimal geometrical relations determination over minimum active...

DETERMINATION OF ECONOMICALLY JUSTIFIED PARAMETERS OF SYNCHRONOUS DISCONNECTION AT LOW-VOLTAGE CIRCUIT SWITCHING VIA A SYNCHRONOUS VACUUM CONTACTOR

Dependence of a single switching procedure cost upon the contact opening delay time and delay-time spread is derived for a low-voltage synchronous vacuum contactor. For different cost levels, boundaries of permissible va...