Point Fire Detectors Arrangement in Special Cases-The slope Roofs case

Abstract

Fire Detectors Arrangement Purports A Great Knowledge And Experience In Fire Protection. Although This Task Was Regulated By Several Valid Standards, It Is Not Always Simple To Realize It. Beside `Normal` Cases For Fire Detectors Arrangement (For Example, Objects With Standard Geometry Shapes) There Can Be Found Lot Of `Special` Cases For Fire Detectors Arrangement. Those `Special` Cases Can Be Stairs, Slope Roofs, Girts, Ventilation System And Similar. They Are Also Regulated By Valid Standards, But There Are Some Differences Between Standards. This Paper Has Written To Present Simulation Results For Smoke Detectors In The Case Of Slope Roof With Different Roof`S Slope, According To VDE 088-2 Standard.

Authors and Affiliations

Radojejevtić . , Milan Blagojević

Keywords

Related Articles

A Survey on Efficient Algorithm for Mining Top-k High Utility Itemsets

High utility thing sets (HUIs) mining is a rising subject in information mining, which alludes to finding all thing sets having an utility meeting a client determined least of utility edge min_util. Not with standing, se...

Parabolic Solar Plate Water Pumping System

Agricultural technology is changing rapidly. Farm machinery, farm building and production facilities are constantly being improved. Agricultural applications suitable for photovoltaic (PV) solutions are numerous. These a...

Synthesis and characterization of some Chromium(III) complexes of dibasic tridentate hydrazone schiff base ligands

Coordination complexes of Cr(III)with four tridentate Schiff base ligands viz. N-(2-hydroxy-1-naphthaldehyde)- -(4-nitrobenzoyl)hydrazone(HNNH = H2L 1 ), N-(2-hydroxy-4-methoxybenzaldehyde)- -(2-furoyl) hydrazone (HMFH =...

“ Study of Sesmic Analysis of Masonry Wall Structure”

Earthquakes are natural trouble under which disasters are mainly caused by damage or collapse of the structure and other man-made structures. When an earthquake occurs natural period of vibration is more on heavy loaded...

Optimization of Thermal Performance on Evacuated Tube Solar Collector Water Heating System

Solar energy is considered one of the main alternative sources of energy to replace the dependency on other fossil resources. Solar water heating are very common systems, extensively used in many countries with high sola...

Download PDF file
  • EP ID EP393906
  • DOI 10.9790/9622-0803042127.
  • Views 105
  • Downloads 0

How To Cite

Radojejevtić . , Milan Blagojević (2018). Point Fire Detectors Arrangement in Special Cases-The slope Roofs case. International Journal of engineering Research and Applications, 8(3), 21-27. https://europub.co.uk/articles/-A-393906