POOR FLEXURAL REINFORCEMENT PLACEMENT FACTOR ON THE PERFORMANCE OF CONSTRUCTED DRAINAGE SYSTEM.

Journal Title: International Journal of Advanced Research (IJAR) - Year 2018, Vol 6, Issue 12

Abstract

Constructional implementation of good structural design that will translate to the require safety and design economy needs good workmanship. Previous structured studies showed that poor workmanship quality would significantly reduce the serviceability reliability and inadequate checks on constructional control resulted in over 90% of project failure. The statistics are worrisome and challenging. No doubt, flexural reinforcement placement at its designated (tensile or compression) place plays a very important in achieving both the strength requirement and satisfying the serviceability condition. However, a case for haphazardly placed flexural reinforcement for lined-drainage during construction of township road that suffers frequent road embankment failure needs further investigation beyond a structured questioner on the effect of poor workmanship. Hence, this study attempts to access the impact of poor placement of flexural reinforcement at its designated zone primarily due to workmanship error using numerical analysis software. The finding reveals that poor flexural reinforcement placement at its design zone will lead to unnecessary stress built-up and this has far-reaching consequences on the performance of the constructed facility. It was found also that a unit change in flexural reinforcement placement position in the tensile zone towards the neutral axis position result in about 3.1% surge in deformation value.

Authors and Affiliations

Kachalla Mohammed.

Keywords

Related Articles

ARTIFICIAL INTELLIGENCE IN DENTISTRY: CURRENT CONCEPTS AND A PEEP INTO THE FUTURE.

The last decade has marked the evolution of artificial intelligence which has been ushered in with tremendous hype and enthusiasm and dentistry is no exception. The tremendous amount of patient data requires intelligent...

ENHANCING STUDENT?S RETENTION OF KNOWLEDGE BY USING DIGESTIVE SYSTEM TEXTBOOK BASED ON PROCESS IMAGES.

Textbooks are still one of the main learning media which used in the Biology learning process. Generally, students are used to using textbooks than digital versions. Basically, Biology is one of the most visual sciences,...

PRELIMINARY INVESTIGATION OF HEMOGLOBIN POLYMORPHISM AND ITS ASSOCIATION WITH SOME MORPHOMETRIC TRAITS AND HEMATOLOGICAL PARAMETERS OF SHEEP AND GOATS IN NORTHEASTERN LIBYA.

Local sheep and goats in northeastern Libya were studied for hemoglobin polymorphism. The study was also aimed to unveil a possible relationship that might exist between hemoglobin genotypes, some selected morphometric t...

PREVALENCE OF REFRACTIVE ERRORS IN 10-16 YEARS OF STUDENTS IN EASTERN BANGALORE, INDIA.

Background:-In eye care refractive error is common cause of avoidable visual impairment though diagnosis and treatment is simple and successful. Aim and Objective: To determine the prevalence of refractive errors amongst...

DEVELOPMENT OF COUNSELING MODEL OF DERADICALIZATION PROGRAM IN INDONESIA: ALTERNATIVE FOR INTEGRATIVE COUNSELING MODEL FOR TERRORISM PRISONERS AS AN EFFORT TO PREVENT AND ERRADICATE THE CRIME OF TERRORISM IN INDONESIA.

The rise of the issue of the radicalism movement in Indonesia recently has made the Indonesian government necessary to review the strategies and efforts that have been made in order to quell the turmoil of radicalism. th...

Download PDF file
  • EP ID EP448085
  • DOI 10.21474/IJAR01/8276
  • Views 26
  • Downloads 0

How To Cite

Kachalla Mohammed. (2018). POOR FLEXURAL REINFORCEMENT PLACEMENT FACTOR ON THE PERFORMANCE OF CONSTRUCTED DRAINAGE SYSTEM.. International Journal of Advanced Research (IJAR), 6(12), 1350-1356. https://europub.co.uk/articles/-A-448085