POOR FLEXURAL REINFORCEMENT PLACEMENT FACTOR ON THE PERFORMANCE OF CONSTRUCTED DRAINAGE SYSTEM.

Journal Title: International Journal of Advanced Research (IJAR) - Year 2018, Vol 6, Issue 12

Abstract

Constructional implementation of good structural design that will translate to the require safety and design economy needs good workmanship. Previous structured studies showed that poor workmanship quality would significantly reduce the serviceability reliability and inadequate checks on constructional control resulted in over 90% of project failure. The statistics are worrisome and challenging. No doubt, flexural reinforcement placement at its designated (tensile or compression) place plays a very important in achieving both the strength requirement and satisfying the serviceability condition. However, a case for haphazardly placed flexural reinforcement for lined-drainage during construction of township road that suffers frequent road embankment failure needs further investigation beyond a structured questioner on the effect of poor workmanship. Hence, this study attempts to access the impact of poor placement of flexural reinforcement at its designated zone primarily due to workmanship error using numerical analysis software. The finding reveals that poor flexural reinforcement placement at its design zone will lead to unnecessary stress built-up and this has far-reaching consequences on the performance of the constructed facility. It was found also that a unit change in flexural reinforcement placement position in the tensile zone towards the neutral axis position result in about 3.1% surge in deformation value.

Authors and Affiliations

Kachalla Mohammed.

Keywords

Related Articles

TECHNOLOGICAL PARAMETERS OF SUGARCANE VARIETIES ATTACKED BY DIATRAEA SACCHARALIS.

An alternative to the control of sugarcane borer is the choice of the more resistant varieties that adapt themselves to different production systems, guarantying a better productivity. This work aimed to evaluate technol...

A STIMULATORY APPROACH FOR IN VITRO ACTIVATION OF HUMAN SPERM MOTILITY BY USING THEOPHYLLINE.

Background: In developed countries, about (2?4%) of births involve the using of assisted reproductive technologies (ART\'s). In these technologies before using semen samples for insemination firstly it must be processed...

THE THIAROYE AQUIFER IN SENEGAL: USABLE GROUNDWATER RESOURCES FOR DRINKING OR IRRIGATION.

The Thiaroye drillings provided for a long time the supply of drinking water to the Dakar region. However, faced with the combined effects of salted bevel advancement and groundwater pollution, state authorities were led...

THE NEED FOR STANDARD OPERATION PROCEDURES FOR UNEXPECTED EVENTS.

Standart operation procedures, as being a set of written instructions that document a routine or repetitive activity followed by an organization, are documents which increase performance of the determined process, so hel...

ASSESMENT OF BYOLOGICALY ACTIVE, TRANS FATTY ACIDS AND QUALITATIVE ASSESMENT ON THE BUTTER FROM COAT?S MILK.

The study was conducted with buter produced by goat\'s milk from three breeds? White Bulgarian Dairy (WBD) and her crosses with Anglo-Nubian (WBDxAN) and Toggenburg goats (WBDxTG) during the lactation to establish the co...

Download PDF file
  • EP ID EP448085
  • DOI 10.21474/IJAR01/8276
  • Views 87
  • Downloads 0

How To Cite

Kachalla Mohammed. (2018). POOR FLEXURAL REINFORCEMENT PLACEMENT FACTOR ON THE PERFORMANCE OF CONSTRUCTED DRAINAGE SYSTEM.. International Journal of Advanced Research (IJAR), 6(12), 1350-1356. https://europub.co.uk/articles/-A-448085