Post-implantation Deformation of Titanium Rod and Cobalt Chrome Rod in Adolescent Idiopathic Scoliosis
Journal Title: Malaysian Orthopaedic Journal - Year 2019, Vol 13, Issue 1
Abstract
Introduction: Post-implantation rod deformation is anticipated in scoliosis surgery but the difference in rod deformation between titanium and cobalt chrome rod has not been elucidated. This study aims to compare the difference in rod deformation between two groups. Materials and Methods: Twenty-one adolescent idiopathic scoliosis (AIS) patients were recruited from a single center. The over-contoured concave rods were traced prior to insertion. Post-operative sagittal rod shape was determined from lateral radiographs. Rod deformation was determined using maximal rod deflection and angle of the tangents to rod end points. The differences between pre- and post-operative rod contour were analysed statistically. Rod deformation and thoracic kyphosis between two types of implants were analysed. Results: Both rods exhibited significant change of rod angle and deflection post-operatively. Curvature of the titanium rod and cobalt chrome rod decreased from 60.5° to 37°, and 51° to 28° respectively. Deflection of titanium rod and cobalt chrome rod reduced from 28mm to 23.5mm and 30mm to 17mm respectively. There was no significant difference between titanium and cobalt chrome groups with regard to rod angle (p=0.173) and deflection (p=0.654). Thoracic kyphosis was increased from 20° to 26° in titanium group but a reduction from 25° to 23° was noticed in cobalt chrome group, but these findings were not statistically significant. Conclusion: There was no statistical difference in rod deformation between the two groups. Thus, the use of titanium rod in correction of sagittal profile is not inferior in outcome compared with cobalt chrome but with lower cost.
Authors and Affiliations
Sia U, Tan BB, Teo YY, Wong CC
Determining if Positive Predictive Value using Laboratory Risk Indicator for Necrotising Fasciitis is Applicable in Malaysian Patients with Necrotising Fasciitis
Introduction: Necrotising fasciitis (NF) is a rapidly progressive infection of the subcutaneous tissue and fascia which spreads rapidly. The scoring system of Laboratory Risk Indicator for Necrotising Fasciitis (LRINEC)...
Normal Anterior Cruciate Ligament Laxity in the Malaysian Population
A study to determine average knee laxity in the Malaysian population and how it affects daily living was conducted at the University Malaya Medical Centre between January and April 2004. Fifty two male and 76 female subj...
Does the Quality of Life in Operated Patients with Adolescent Idiopathic Scoliosis correspond with the Radiographic Parameters?
Objectives: Traditionally, scoliosis surgery is aimed at attaining a fused, balanced and painless spine. With improvement in surgical and instrumentation techniques, spine surgeons strive to achieve higher degree of Cobb...
Transtubular Transoral Surgery for Excision of a Dystrophic Os Odontoideum: A Case Report
Transoral approach to the cervico-medullary junction is a well-established procedure. However oropharyngeal complications in the form of soft tissue morbidity postoperatively do occur. We report a case of a teenage boy w...
A Computer Navigation System Analysis of the Accuracy of the Extramedullary (Tibial) Alignment Technique in Total Knee Arthroplasty (TKA)
In total knee arthroplasty, mechanical alignment guides have improved the accuracy of implant alignment, but errors are not uncommon. In the present study, an image-free computer-assisted navigation system was used to an...