Abstract

Long distance AC transmission is often subjected to certain problems which limit the transmission capability. HVDC is a better option for transmission of power over long distances. Power is being transmitted between two generating stations via dc link. The control of power flow in DC link can be achieved through control of current or voltage. For minimization of loss considerations, it is important to maintain constant voltage in link and adjust current to meet required power. In this project, a HVDC system is designed to control the power flow between two converter stations with conventional PI controller and Artificial Neural Networks. For rectifier side current control is used for inverter side both current and extinction angle control is implemented. The error signal is passed through a PI and Artificial Neural Networks controller, which produces the necessary firing angle order. The firing circuit uses this information to generate the equidistant pulses for the valves in the converter station. Here Artificial Neural Networks is designed for both rectifier and inverter control and its performance is compared with conventional PI controller.

Authors and Affiliations

S. Sai Charan, Prof. GopiChand Naik Mudavath

Keywords

Related Articles

A Novel Approach to Build a Gated Integrator for HighResolution Energy Spectroscopy Systems

A gated integrator (GI) is to solve the ballistic deficit problem by integrating the signal until all the charge is collected from the detector. With the development of radioactive ion beam physics, heavy-charged particl...

Water Wave Optimization Algorithm for solving Thermal Unit Maintenance Scheduling

Maintenance scheduling of generating units is considered one of the vital power system problem for providing power in a reliable and economic way. In order to improve the overall availability of the generating units, cha...

Object Gripping With Automated Robotic Arm Movement

In the upcoming era of advanced technology, for the ease of the human being living, industrial automation with lesser human effort and all other possible application areas are enriched with the ever growing features of t...

Hybrid PSO-GSA Applied To Dynamic Economic Dispatch With Prohibited Operating Zones

This paper proposes a novel and efficient hybrid algorithm based on combining particle swarm optimization (PSO) and gravitational search algorithm (GSA) techniques, called PSO-GSA. The core of this algorithm is to combin...

Design of Wireless Measuring Terminal for Absolute Position and Displacement of Railway Track Based on PSD Position Sensor

With the large-scale application of seamless rail in China, the workload of front-line railway maintenance workers has also greatly increased, and the traditional manual "two times measurement method" has been unable to...

Download PDF file
  • EP ID EP388975
  • DOI 10.9790/1676-1305011020.
  • Views 127
  • Downloads 0

How To Cite

S. Sai Charan, Prof. GopiChand Naik Mudavath (2018). Power Flow Control And Total Harmonic Distortion Reduction In HVDC Link Using PI And ANN Controllers. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(5), 10-20. https://europub.co.uk/articles/-A-388975