Power Loss Evaluation Method for Modular Multi-Level Converter with High-Frequency

Abstract

There is no common accepted way for calculating the valve power loss of modular multilevel converter (MMC). Valve power loss estimation based on analytical calculation is inaccurate to address the switching power loss and valve power loss estimation based on detailed electro-magnetic simulation is of low speed. To solve this problem, a method of valve power loss estimation based on the detailed equivalent simulation model of MMC is proposed. Results of valve power loss analysis of 201-level 500MW MMC operating at 50Hz~1000Hz are presented. It is seen that the valve power loss of a MMC increased by 12, 40 and 93 % under 200Hz, 500Hz and 1000Hz operating frequency. The article concludes that in a device with isolated inner AC system, MMC operating at higher frequency will be more competitive than typical 50Hz/60Hz MMC with moderate increase of operating power loss and significant reduction of the size of the AC components. Gangadhara Swamy | Molugu Shruthi"Power Loss Evaluation Method for Modular Multi-Level Converter with High-Frequency" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-2 | Issue-1 , December 2017, URL: http://www.ijtsrd.com/papers/ijtsrd7027.pdf http://www.ijtsrd.com/engineering/electrical-engineering/7027/power-loss-evaluation-method-for-modular-multi-level-converter-with-high-frequency/gangadhara-swamy

Authors and Affiliations

Keywords

Related Articles

Detecting Malicious Facebook Application using Digital India Scheme

With 20 million installs a day third-party apps are a major reason for the popularity and addictiveness of Facebook. Unfortunately, hackers have realized the potential of using apps for spreading malware and spam. The pr...

Isolation and Optimization of Protease Producing Bacteria from Marine Sediment

In the present study investigation protease producing potent bacterial strain was isolated from the Marine sediment soil. Based on the morphology, biochemical and 16S rRNA sequencing, it was identified as Oceanobacillus...

Pontem Monitoring using IoT

In recent years, many of the bridges are monitored using non-destructive testing methods. These methods are used for checking the structural damage, wreckage, strength of the bridges. To reduce the human losses, economic...

Customer Satisfaction A Case Study of Mongolia Banking Sector

The aim of this work is to assess the degree of customer satisfaction in the banking sector in Mongolia based on customer perceptions of service quality. The questionnaire was personally conducted on a sample of 150 bank...

A Research on Cluster Based Routing Methodologies for Wireless Sensor Networks

The design of Wireless sensor networks has currently significant attention due to their limitless potential and has great value of applications such as not closely connected environmental monitoring and target tracking....

Download PDF file
  • EP ID EP358707
  • DOI -
  • Views 112
  • Downloads 0

How To Cite

(2017). Power Loss Evaluation Method for Modular Multi-Level Converter with High-Frequency. International Journal of Trend in Scientific Research and Development, 2(1), -. https://europub.co.uk/articles/-A-358707