Power of impulse transmission.

Abstract

he work is devoted to the transfer of energy by pulses of electric current along a conducting line from the source to the consumer. The analysis of the transmissions by pulses from DC and AC sources is made and comparison with analog transmissions is made. A technology is proposed that provides for the transfer of energy accumulated in the magnetic field of the line to the reservoir. The capacitance functions as a collector, the localization of energy near the load and the formation of a current pulse. The transmission efficiency of pulses can be higher than analo g transmission. To confirm the analytical dependencies, a harmonic analysis of the impulse energy transfer is performed: the energy parameters are represented by a harmonic series, the series expansion is checked, and the efficiency of the pulse and analog transmissions is compared. The increase in efficiency occurs, in particular, due to the lack of circulation of the energy of the magnetic field of the line during transmission from an alternating current source.

Authors and Affiliations

Mark CHASHKO, S. N. ZINOVYEV, N. A. NESTORUK

Keywords

Related Articles

IMPROVING CURRENT PROTECTION AGAINST SHORT CIRCUIT OF SMART-GRID 6–35 KV NETWORK USING STRUCTURAL-INFORMATION METHOD. PART 1. ANALYSIS

A proposed method is presented for methodical improvement of the algorithms of relay pro-tection and automation for the implementation of the concepts of "Smart -grid", "Digital cell", "Digital substation", and "Outsour...

Microprocessor device for the diagnosis of capacitors DC link bus of frequency converters.

The paper presents a theoretical and applied aspects of implementation diagnosing microprocessor for filtering electrolytic capacitor DC link frequency converters The synthesis of hardware and software necessary to bui...

Analysis of the operation of the steam turbine at rated parameters.

To describe the turbine workflow, we consider the design of the flow section of a multi-stage steam turbine of a condensing type. The turbine flow section consists of degrees. Dependencies depending on the direction of f...

Heat losses minimization during demagnetization process in vector-controlled induction motor.

Analysis of heat losses during demagnetization of motor windings has been done for induction machine in direct field -oriented control system. Euler’s optimization method was used for solving the problem of finding the...

Hybrid Multilevel Converter of medium voltage.

For the medium-voltage frequency converters are used: a cascade connection inverters (up to 10 kV) and three-level NPC inverters (up to 4.16 kV). ABB released a converter type ACS 2000 with active-neutral-point-clamp...

Download PDF file
  • EP ID EP660740
  • DOI -
  • Views 169
  • Downloads 0

How To Cite

Mark CHASHKO, S. N. ZINOVYEV, N. A. NESTORUK (2017). Power of impulse transmission.. Наукові праці Донецького Національного Технічного Університету серія: Електротехніка і Енергетика, 1(1), 50-55. https://europub.co.uk/articles/-A-660740