Power Quality Analysis of Harmonics in3.5kVA Single Phase Generator using Electronic Filter in Matlab/Simulink Environment.

Abstract

The aim of this workis to investigate the harmonic content of nonlinear loads connected to 3.5kVA power supply source and to mitigate the effects using electronic filter (double tuned low pass active shunt filter).The presence of harmonics was investigated by collecting data from the power source, 3.5 kVA using „Owon Oscilloscope‟ metering device. The data was then processed by means of Fourier analysis into harmonic spectrums. Mitigate the harmonics found in this power source a double tuned low-pass active shunt filter was design from discrete elements (resistors, capacitors and inductors) and implemented in the MATLAB/SIMULINK environment.The result obtained for VTHD before and after the simulation procedure using the series active passive filter was higher than the expected IEEE standard of 5%; while the result obtained using the double tuned low pass active shunt filter then after simulation gave a satisfactory result less than the expected IEEE standard of 5% after simulation.

Authors and Affiliations

Dr. Eyenubo Ogheneakpobo Jonathan, Prof. Emmanuel U. Ubeku

Keywords

.

Related Articles

Drought Index Analizes With Rainfall Patern Indicators Use SPI Method (Case Study Bangga Watershed)

Irregular weather and climate changes caused by El – Nino effect drought in some areas, including in Indonesia. The location of this study lies in the Bangga watershed. The purpose of this study was to determine rainfall...

Using Differential Transform Method To Solve Non-Linear Partial Differential Equations

Following the early application in electrical circuits, differential transform method for solving non-linear partial differential equations is gaining recognition based on the effectiveness of the solutions. This study s...

“Behavior of Seam Puckering of Polyester, Cotton & blends fabric on High Sewing Thread Tension”

The garment quality means the quality ofseam, which is the very important feature of any form of fabric assembly using sewing operations. The investigation has attempted to find out the relationship between fabric elonga...

Brief Review of Image Segmentation Techniques Based On Markov Random Field Model

Picture Segmentation Comes Out To Be The Most Fundamental But Difficult Issues In PC Vision Among All. When Study And Understanding A Picture, Individuals Are Frequently Keen In The Particular Regions, Which Have Almost...

Performance Study of Square Footing Resting Over Geo-Grid Reinforced Sand

Decreasing availability of good construction sites and increasing construction activities for infrastructural developments throughout the world has forced the civil engineers to utilize unsuitable sites or weak soil. So...

Download PDF file
  • EP ID EP393661
  • DOI 10.9790/9622-0801054549.
  • Views 81
  • Downloads 0

How To Cite

Dr. Eyenubo Ogheneakpobo Jonathan, Prof. Emmanuel U. Ubeku (2018). Power Quality Analysis of Harmonics in3.5kVA Single Phase Generator using Electronic Filter in Matlab/Simulink Environment.. International Journal of engineering Research and Applications, 8(1), 45-49. https://europub.co.uk/articles/-A-393661