Power Quality Improvement By Svc Using PIC18F4

Abstract

Power quality improvement for non linear loads is the point of interest for researchers in recent years. Power factor plays an effective role in efficiency of electrical system. In power system the voltage level at different system changes with the change in load. The voltage level at the load must be maintained within required range irrespective of the type & magnitude of the load. For maintaining voltage fixed within limits, it is necessary to maintain the balance of reactive power in the system as reactive power is related with voltage directly.i.e reactive power generation and absorption must be equal. Any mismatch occurs in the reactive power balance affects the bus voltage magnitude. A static VAR compensator include capacitor bank in different binary sequential steps in conjunction with a thyristor controlled reactor of minimum step size is used in the investigative work. The work related with the performance evaluation through analytical studies and practical implementation on an existing system consisting of a distribution transformer of 1 PH phase 50 Hz, 1KV/230V capacity. The switching characteristics achieved are transient free, practically no need to provide inrush current limiting reactors, TCR size minimum providing minimum percentages of nontriplen harmonics, facilitates stepless variation of reactive power depending on load requirement , thus maintain power factor near always unity .

Authors and Affiliations

Mr. Vijay S. Gadakh, Dr. Dinesh M. Chandwadkar

Keywords

Related Articles

Hypothesis On Using Biogas and Hydrogen obtained from waste biomass and waste water in HCCI engine

Automatic sweeper under the vehicle automatically sweeps the waste from road and collects it to container at the rear side though a blower From where, the waste is separated into 2 chambers: 1 for fermentation, where or...

Analytical Representation on Secure Mining in Horizontally Distributed Database

The security of the large database becomes a serious issue while sharing the data to the network against unauthorized access. However in order to provide the security many researchers cited the issue of Secured Multipar...

Service-Oriented Applications Based On an Enterprise Service Bus

The concept of enterprise service bus has been originally invented to reduce complexity of enterprise application integration within an enterprise. Enterprise service bus (ESB) is a software architecture model used for...

Congestion Management in a Deregulated Power System Using Fuzzy Logic with IPFC

Congestion management is a major problem that the independent system operator would face in scheduling and rescheduling process in a deregulated electricity market era. One of the most practiced, an obvious method is co...

Effects caused on Leaky integrate and fire model

for analyzing the behaviour of neural system, the model used most widely is integrate and fire model. The membrane potential of a neuron in terms of injected current and synaptic inputs is described by integrate and fir...

Download PDF file
  • EP ID EP24736
  • DOI -
  • Views 408
  • Downloads 14

How To Cite

Mr. Vijay S. Gadakh, Dr. Dinesh M. Chandwadkar (2017). Power Quality Improvement By Svc Using PIC18F4. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 5(6), -. https://europub.co.uk/articles/-A-24736