Power transformer station 330/110 kV power lines in the presence of harmonics

Abstract

Disabling or damage to overhead power lines of high and extra-high voltage (power lines) caused by various reasons, among which is not the last place is occupied by both natural factors - the effects of lightning and birds or wind loads, icing and contamination of insulators in regions with unfavorable environmental conditions, and accidental or deliberate human actions on the damage to the outboard isolation.

Authors and Affiliations

O. G. Gryb, S. Yu. Shevchenko, D. A. Gapon, Yu. А. Sirotin, T. S. Ierusalimova, A. V. Diachenko

Keywords

Related Articles

Comparison of electromechanical parameters of an induction-dynamic motor and an electromagnetic motor

Comparison of electromechanical indicators of an induction-dynamic motor and an electromagnetic motor, designed to work as an actuator of electrical switchgears is carried out. Motors with the same weight and size parame...

Effect of frequency on distribution of current density and on heating of printed boards

Introduction. The article deals with the distribution of the current density and the heating of the conductors of the printed circuit board, depending on the frequency of the source at a fixed value of the current. In th...

Aspects of the mathematical modelling of the elements for Western Systems Coordinating Council of combined propulsion complexes

On the basis of analysis of well-known mathematical models of elements of electric power systems has been proposed a method of improving the management system for the inverter power induction motor thruster Special Purpo...

DSTU IEC Standards: house without foundation…

A comparison of organizational and methodological approaches to the creation of the standards of the International Electrotechnical Commission (IEC) and national standards DSTU IEC. It is proposed to begin systematic wor...

Simulation of control axial flux permanent magnet generator

This article gives analysis and comparison of control system and stabilization external characteristic of axial flux generator. A technical solution is proposed that allow to control and stabilize external characteristic...

Download PDF file
  • EP ID EP408854
  • DOI -
  • Views 132
  • Downloads 0

How To Cite

O. G. Gryb, S. Yu. Shevchenko, D. A. Gapon, Yu. А. Sirotin, T. S. Ierusalimova, A. V. Diachenko (2015). Power transformer station 330/110 kV power lines in the presence of harmonics. Вісник Національного технічного університету "ХПІ". Серія: Проблеми удосконалювання електричних машин і апаратів. Теорія і практика, 42(1151), 59-61. https://europub.co.uk/articles/-A-408854