Practical implementation of the SWEEP-session of Stimulation-Registration in CI fitting
Journal Title: Advanced Treatments in ENT Disorders - Year 2017, Vol 1, Issue 1
Abstract
Levels of electrically evoked stapedial reflex thresholds (eESRTs) are frequently used as most comfortable levels (MCL) in cochlear implant fitting. The problem of routine one-channel-technique of reflexometry is long duration of this procedure. In order to “compress the time” we suggest method of consecutive stimulation of all electrodes of implant with simultaneous registration of stapedial reflexes-SWEEP-session. Practical implementation of the SWEEP-session is described here. This method has been successfully used in several hundred CI patients. Registration of evoked electrical stapedial reflex thresholds (eESRTs) during CI fitting is long procedure. In order to “compress the time” we suggest our SWEEP-session method. Practical implementation of this SWEEP-session is described here in accordance with the patent of Russian Federation.
Authors and Affiliations
Petrov SM
Recent advances in pathophysiology and management of subglottic Hemangioma
Subglottic hemangioma is the most common vascular tumor of the larynx of pediatrics; in contrast, it is relatively uncommon, accounting for an estimated 1.5% of congenital laryngeal anomalies [1].
Changes in the frequency and intensity of Tinnitus using the Suppressive Noise Spectrum
Objective:To report findings of improvement in patient tinnitus intensity and changes in frequency using a novel suppressive noise spectrum. Design: Single-subject; each subject served as his or her own control. Each pa...
A possible Etiology and new treatment of Burning Mouth Syndrome and allied condition
Introduction: Burning mouth syndrome, oral sub mucous fibrosis, leukoplakia, etc are the different manifestations of a common disease as per the surmise of various authors. There is no known cause and no specific treatme...
Practical implementation of the SWEEP-session of Stimulation-Registration in CI fitting
Levels of electrically evoked stapedial reflex thresholds (eESRTs) are frequently used as most comfortable levels (MCL) in cochlear implant fitting. The problem of routine one-channel-technique of reflexometry is long du...
For professionals working on the topic of cochlear implantation: Opinions of readers of “Instruction” and participants of MIMIC
To facilitate understanding some issues of cochlear implantation for new beginners we wrote 1- “The Instruction for audiologists and cochlear implanted patients” and created 2-Demo-program MIMIC. Here are opinions of rea...