Abstract

Autografts are the current gold standard for large peripheral nerve defects in clinics despite the frequently occurring side effects like donor site morbidity. Hollow nerve guidance conduits (NGC) are proposed alternatives to autografts, but failed to bridge gaps exceeding 3 cm in humans. Internal NGC guidance cues like microfibres are believed to enhance hollow NGCs by giving additional physical support for directed regeneration of Schwann cells and axons. In this study, we report a new 3D in vitro model that allows the evaluation of different intraluminal fibre scaffolds inside a complete NGC. The performance of electrospun polycaprolactone (PCL) microfibres inside 5 mm long polyethylene glycol (PEG) conduits were investigated in neuronal cell and dorsal root ganglion (DRG) cultures in vitro. Z-stack confocal microscopy revealed the aligned orientation of neuronal cells along the fibres throughout the whole NGC length and depth. The number of living cells in the centre of the scaffold was not significantly different to the tissue culture plastic (TCP) control. For ex vivo analysis, DRGs were placed on top of fibre-filled NGCs to simulate the proximal nerve stump. In 21 days of culture, Schwann cells and axons infiltrated the conduits along the microfibres with 2.2 ± 0.37 mm and 2.1 ± 0.33 mm, respectively. We conclude that this in vitro model can help define internal NGC scaffolds in the future by comparing different fibre materials, composites and dimensions in one setup prior to animal testing.

Authors and Affiliations

Mehri Behbehani, Adam Glen, Caroline S. Taylor, Alexander Schuhmacher, Frederik Claeyssens, John W. Haycock

Keywords

Related Articles

In vitro model of the glial scar

The trauma of central nervous system (CNS) can lead to glial scar, and it can limit the regeneration of neurons at the injured area, which is considered to be a major factor affecting the functional recovery of patients...

A dual crosslinking strategy to tailor rheological properties of gelatin methacryloyl

3D bioprinting is an emerging technology that enables the fabrication of three-dimensional organised cellular constructs. One of the major challenges in 3D bioprinting is to develop a material to meet the harsh requireme...

Optimization of a 3D bioprinting process using ultrashort peptide bioinks

The field of three-dimensional (3D) bioprinting is rapidly emerging as an additive manufacturing method for tissue and organ fabrication. The demand for tissues and organ transplants is ever increasing, although donors a...

Patterning of tissue spheroids biofabricated from human fibroblasts on the surface of electrospun polyurethane matrix using 3D bioprinter

Organ printing is a computer-aided additive biofabrication of functional three-dimensional human tissue and organ constructs according to digital model using the tissue spheroids as building blocks. The fundamental biolo...

Multicomponent bioprinting of heterogeneous hydrogel constructs based on microfluidic printheads

Multimaterial bioprinting provides a promising strategy to recapitulate complex heterogeneous architectures of native tissues in artificial tissue analogs in a controlled manner. However, most of the existing multimateri...

Download PDF file
  • EP ID EP678679
  • DOI -
  • Views 160
  • Downloads 0

How To Cite

Mehri Behbehani, Adam Glen, Caroline S. Taylor, Alexander Schuhmacher, Frederik Claeyssens, John W. Haycock (2018). Pre-clinical evaluation of advanced nerve guide conduits using a novel 3D in vitro testing model. International Journal of Bioprinting, 4(1), -. https://europub.co.uk/articles/-A-678679