Abstract
Purpose. This work is devoted to method developing for quantify assessment of the electrodes contact with myocardial tissue during catheter radiofrequency ablation. It will allow to perform forecasting destruction efficiency by visualizing them in three-dimensional internal surface of the heart in the color spectrum. Methodology. Original automated system is developed in the programming environment Matlab that can work with application of all types of catheters and digital map data of individual anatomy of the heart and destruction points derived from the electro-anatomical mapping system Ensite Velosity NavX (St. Jude medical, USA). The construction of three-dimensional model of the heart is performed and the radiofrequency destruction points are superimposed on it in a color spectrum corresponding to different distances electrode to myocardial tissue during ablation. Results and practical value. The assessing method of electrodes contact with myocardial tissue during catheter radiofrequency ablation is confirmed its accuracy and efficiency in clinical practice. It is introduced in State Institution "M.M. Amosov National Institute of Cardiovascular Surgery at NAMS of Ukraine" for control and predicting of tissue destruction effectiveness in the left atrium around pulmonary veins and isthmus between the veins and valves to block the spread of potential that lead to fibrillation and atrial flutter.
Authors and Affiliations
M. Sychyk, V. Kovshevatska, L. Tarasova
Regulated four tact transistor inductance
Marketability function of inductance is considered as a four tact structure on the base of transistors of different polarity and its analysis is conducted. Application of such structure at symmetry of it shoulders substa...
Signals Features from Distributed Targets of Autodyne SRR with Simultaneous Pulse Amplitude and Linear Frequency Modulations
A mathematical model for signals description of the autodyne short-range radar (ASRR) with the simultaneous pulse amplitude modulation (PAM) and the linear frequency modulation (FM) is considered. The peculiarities of si...
Metalоdetectors
This article is an overview of all currently existing principles of finding metals -magnetic and nonmagnetic. The main attention is focused on advanced models. Presents the comparative characteristics of various types of...
Research of resisting of the biological active point for constant and alternative current
Is conducted research of resistance of biologically active point (BAT) on a direct and variable current. Research results are presented. The estimation of intercommunication between resistance of skin and by an electroma...
The macroscopic analysis of ergatic systems
Introduction. System "man-machine" (ergatic system) is characterized by the extreme complexity of the internal and external relationships and their dependence on a very large number of factors. Macroscopic analysis makes...