Prediction of Distribution Transformer Premature Failures
Journal Title: International Journal for Research in Applied Science and Engineering Technology (IJRASET) - Year 2017, Vol 5, Issue 5
Abstract
This paper deals with two types of Distribution Transformer failure analysis tests which can help in monitoring the Distribution Transformers condition. The three methods are Conventional oil test, Furan derivatives test. Conventional oil testing procedures determine the gas concentrations in the Distribution Transformers oil sample and analysing the defect by considering the ratio of two suitable gasses. Furan derivative analysis includes determination of Furan derivatives present in the Distribution Transformers oil sample and helps in deciding the Distribution Transformers insulation condition. A computer program was developed for which that can help in finding out the fault probability of the Distribution Transformer. Here, we demonstrate the application of these three methods on a 132/33kV, 15MVA Distribution Transformer from CSEB substation, Korba Bilaspur, India, under three different conditions namely healthy, moderately deteriorated and extensively deteriorated conditions and results obtained.
Authors and Affiliations
Tarini Dewangan, Miss Pragya Patel
Evolutionary Technique for Network Routing
Applying mathematics to a problem of the real world mostly means, at first, modeling the problem mathematically, maybe with hard restrictions, idealizations, or simplifications, then solving the mathematical problem, an...
Frequent Items Mining in Data Streams
The main goal of this research is to mine frequent items in data streams using ECLAT and Dynamic Itemset Mining algorithms and finding the performance and drawbacks of these two algorithms. Most commonly used traditiona...
slugEnergy Efficient & Secured Group Communication in MANET using RBMULTICAST Protocol
Energy is one of the main issues to be discussed in MANET Sensor network. Since each sensor node is powered by a battery which is not rechargeable and it is not possible to change the batter. Prior creation of a multica...
Survey Paper on Circular Aperture Slot Antenna with Defected Ground Structure for Broad Band
This paper introduces the survey on the circular Aperture Sot Antenna with defected ground structure. A novel system composed of a circular aperture slot antenna and a Common-Mode (CM) noise rejection filter is presente...
Strength Analysis of Steel Fiber Reinforced Concrete with Different Types of Curing
Concrete is a composite material containing hydraulic cement, water, coarse aggregate and fine aggregate. The resulting material is a stone like structure which is formed by the chemical reaction of the cement and water...