PROBLEMS IN TESTING DIGITAL PROTECTIVE RELAY FOR IMMUNITY TO INTENTIONAL DESTRUCTIVE ELECTROMAGNETIC IMPACTS. CONTINUATION OF THE THEME

Abstract

The article is the continuation of the theme highlighted in the previous article with same title. The new article evaluates the results of digital protective relays (DPR) testing for immunity to the E1 component of High-altitude Electromagnetic Pulse (HEMP) and to Intentional Electromagnetic Interferences (IEMI) impacts, conducted by some independent American organizations; discusses the features of relay protection devices as well as clarifies and supplements the procedure for testing these devices. Due to methodology errors during the DPR tests conducted by mentioned organizations earlier, they cannot be considered as satisfactory and their results as meaningful. At the moment there are no reliable data on the level of DPR immunity to IDEI, which suggests that the test should be conducted further.

Authors and Affiliations

Vladimir I. Gurevich

Keywords

Related Articles

CALCULATION OF THE EQUIVALENT ELECTRICAL PARAMETERS OF THE INDUCTOR OF INDUCTION CHANNEL FURNACE WITH DEFECTS IN ITS LINING

Aim. The aim of the paper is to determine a quantitative relationship between measured impedance of the inductor and the electrical characteristics of the separated melt circuit parts for the determination of the place o...

AN ANTHOLOGY OF OUTSTANDING ACHIEVEMENTS IN SCIENCE AND TECHNOLOGY. PART 22: INVENTION OF ELECTRIC ENERGY ACCUMULATORS

A brief essay on the history of inventing the main types of accumulators that store and supply electric energy to consumers is given.

INVESTIGATION OF A LINEAR PULSE-INDUCTION ELECTROMECHANICAL CONVERTER WITH DIFFERENT INDUCTOR POWER SUPPLY CIRCUITS

Purpose. The goal of the paper is to investigate the influence of the power circuits of the linear pulse-induction electromechanical converters (LPIEC), which form the current pulse of excitation of the inductor from the...

METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS

Purpose. To analyze the transient processes in the charge circuit of electric discharge installations with two capacitors, taking into account the change in the initial conditions of such processes (initial voltage on th...

GUARANTEEING THE TROUBLE-FREE OPERATION OF CAPACITOR BANKS IN POWER-SUPPLY SYSTEMS OF INDUSTRIAL ENTERPRISES

Purpose. The problem of resonance phenomena in power systems of industrial enterprises using capacitor banks for reactive power compensation was detected. Circuit of the capacitor banks tier to downshift main substation...