Problems of neurotoxicity assessment with using of electroretinography

Abstract

Introduction. An actual problem of detection neurotoxication from getting nanoparticles into the human body in its initial stage, the identification of toxicant, determine its amount (dose) is considered. Formulation of the problem. The solving of the basic problems which encountered during improving electroretinography means and methods in its application to risk assessment person neurotoxication are considered in this article. Directions of retinographia improvement. We propose a method to improve of the standard electroretinography tools for assessment of risk of neurotoxicity. On the basis of the concept of applying with low intense pulsed light exposure on to the retina leads to a large resolution and less recovery time of the retina. A negative effect of reducing the intensity of the light obtained in the form of decrease of ratio energies of electroretino - signal to noise (ER-SNR). The application of the optimal Kalman filter to estimate the electroretinosignal in the selected from the retina its mixture with noise is based. The main results cited as simulation, and the field experiment. The statistical test of whether the alternative hypothesis achieves the predetermined significance level in order to be accepted in preference to the null hypothesis was applied. The formulas for entropy expressions in stationary and periodical correlated models of ERS are proposed. Conclusion. The results are used in development of an expert system for detecting of neurotoxicity, identification of nanoparticle type, and estimation of their dose in the nervous system of an organism, including at cases of a priori unknown particle.

Authors and Affiliations

R. Tkachuk, B. Yavorskyy, A. Yanenko

Keywords

Related Articles

Using N-push principle for the microwave transistor oscillators design

The features and advantages of the N-push microwave transistor oscillators design are discussed.

The history essay: radiotechnical faculty of NTUU "KPI"

History of the fundament and development of the radiotechnical faculty of NTUU "KPI" are accounted. Information about his structure, achievements of the teachers in education and science are quoted.

Wireless technologies of data transfer Wi-Fi, Bluetooth and ZigBee.

This paper describes Wireless technologies of data transfer: Wi-Fi, Bluetooth and ZigBee. There are comparison characteristics of these technologies and possible application area for these technologies.

The nonlinear radar testing on the reliability of the objects’ identification

The nonlinear radar testing using a single wideband simulator of the laying device is considered. It is shown that the simulator on the basis of the flat two-armed spiral antennas with semiconductor diode in the load has...

Enhancement of the low-intensity noise generator efficiency

Introduction. The low-intensity noise generators of millimeter wavelength range find wide application in the engineering, biological appliance and therapy procedures due to the simplicity, reliability and efficiency at t...

Download PDF file
  • EP ID EP308789
  • DOI 10.20535/RADAP.2015.61.108-115
  • Views 76
  • Downloads 0

How To Cite

R. Tkachuk, B. Yavorskyy, A. Yanenko (2015). Problems of neurotoxicity assessment with using of electroretinography. Вісник НТУУ КПІ. Серія Радіотехніка, Радіоапаратобудування, 0(61), 108-115. https://europub.co.uk/articles/-A-308789