Protective Measures for a Tunnel on Xi’an Metro Line 6 Crossing Ground Fissure Zone

Journal Title: Urban Mass Transit - Year 2024, Vol 27, Issue 8

Abstract

Objective Xi’an Metro Line 6 Phase Ⅱ project encounters seven ground fissures along one of its tunnels, the poor engineering properties may cause partial tunnel collapse and uneven settlement at the base, exacerbating ground fissure activities and posing serious threats to the construction and operation of urban rail transit. Therefore, it is essential to study protective measures for this Line 6 tunnel crossing ground fissure zones. Method Based on the historical activity characteristics of the ground fissures intersecting Xi’an Metro Line 6 Phase Ⅱ project, a qualitative evaluation of the impact levels of each fissure on metro is conducted. Combining this qualitative evaluation results with the spatial relationship between the tunnel and the fissures, as well as the design value of recommended maximum vertical displacement for the fissures during a 100-year service life, estimates are made for the vertical, horizontal and axial displacements of the fissures and the longitudinal protective length of tunnel structure. According to the engineering prevention principles for Class Ⅱ ground fissure sites, corresponding protective measures are proposed for the tunnel crossing fissure zones. Result & Conclusion The protective measures for a Xi’an Metro Line 6 tunnel crossing ground fissure zones include: adopting segmental seams for tunnel lining structure, increasing tunnel cross-sectional clearance, reinforcing local linings, and using flexible joints at the seams. These protective measures successfully ensure the safe construction and operation of seven metro lines.

Authors and Affiliations

Ziquan HU, Ming SHA, Yinlin HU, Changchun YAO, Jiang RUI

Keywords

Related Articles

Fire Smoke Control and Personnel Safety Evacuation under Dual-train Tracking Mode in Urban Rail Transit Ultra-long Tunnel

Objective In urban rail transit, train departure intervals are generally short, leading to situations where two trains travel in the same direction within ultra-long tunnels. In the event of a fire, this scenario can res...

Influence of Urban Rail Transit Carbody Vertical Vibration on Pantograph-catenary Current Collection Performance

Objective Most existing studies on catenary system dynamics simulation are based on the assumption that the pantograph base has only longitudinal degrees of freedom, neglecting the influence of carbody vertical vibration...

Application of New Electricity Saving Technology in Urban Rail Transit Depot

[Objective] The electricity consumption in vehicle depot accounts for a large proportion of the total in urban rail transit. In order to reduce the depot electricity consumption, it is necessary to do research on the app...

Segmental Power Supply Scheme and Fault Identification Method for Urban Rail Transit Traction Network in Continuous Co-phase Power Supply Mode

Objective When urban rail transit line adopts the continuous co-phase power supply mode, a fault in the traction network may cause extended power outage due to the complexity and non-backup structure of the traction netw...

Metro Construction Personnel Safety Management System Based on BIM Technology and Smart Construction site Concept

[Objective] Unsafe behaviors among personnel are significant factors contributing to safety accidents in rail transit engineering. To address the existing issues of video image monitoring systems, such as reliance on man...