Pulmonary function tests in stainlesssteel utensil polish workers-a cross sectional study

Journal Title: INTERNATIONAL JOURNAL OF CURRENT RESEARCH - Year 2016, Vol 8, Issue 7

Abstract

Introduction: The pulmonary function tests give an objective assessment of the functional status of the respiratory system and indicate the nature and extent of the functional disturbance in disorders associated with pulmonary impairment and disability. Spirometry is valuable in industrial medicine, to study the lung involvement in occupational diseases which occur in workers of textile mills, coal mines and other occupations in which they are exposed to various forms of air pollutants. Several research workers have confirmed the ill effects of air pollutants on respiratory functions of human being. In stainless steel utensil polishing industries the workers are exposed to carbon black and chromium dust. This prompted us to undertake this study to assess the pulmonary function tests in the stainless steel utensil polish workers. Aim: To perform pulmonary function test in stainless steel utensil workers to evaluate and analyze whether long term occupational exposure to stainless steel utensil polishing dust which contains carbon black and chromium affects lung functions. Materials and Methods: This cross sectional study was carried out to assess and evaluate the effects of stainless steel utensil polishing dust on the lung function. The study involved 65 male workers exposed to stainless steel utensil polishing dust and 50 healthy individuals as control group. The workers were aged between 18-32 years and the duration of employment was above 5 years. The control group also aged between 18-32 years. The micromedical superspiro was used for this study. The procedure was explained to the subject repeatedly in detail. The maneuver was demonstrated to each subject separately before performing the test. The pulmonary function test was conducted by seating the subject comfortably in chair with spine erect position. The following functional parameters, Forced Expiratory Volume in first second (FEV1), Forced Vital Capacity (FVC), Peak Expiratory Flow Rate (PEF), FEV1 as percentage of VC (FEV1/VC), Maximum Expired Flow Rate at 75%, 50%, 25% of FVC remaining such as MEF75, MEF50, MEF25, Mean Mid Expiratory Flow Rate (MMEF Or FEF 25-75%), Maximum Voluntary Ventilation Indicated (MVV Ind), Forced Inspiratory Volume In First Second ( FIV1), Forced Inspiratory Vital Capacity (FIVC), Peak Inspiratory Flow Rate (PIF), Maximum Expiratory Flow Rate 50/ Maximum Inspiratory Flow Rate 50 (MEF50/ MIF50), Forced Expiratory Time (FET) were studied. Results: The FEV1, FVC, PEF, FEVI/FVC, MEF50, MEF25, MMEF, MVVInd, FIV1, FIVC, PIF, MEF50/ MIF50 and FET values were used for this study. The data collected were statistically analysed by using students‘t’- test. Having analysed the results in our study the following was inferred. The FEV1, FVC, PEF, MEF75, MEF50, MMEF, MVVInd, FIV1, FIVC, PIF, FET showed significant decrease in stainless steel utensil polish workers than control group. The FEV1/ FVC, MEF50/ MIF50, MEF25 showed a slight increase in stainless steel utensil polish workers when compared to control group, suggesting a restrictive pulmonary parenchymal disease. Conclusion: As per the PFT results, among the 65 polish workers 26 workers have mild restriction, 16 workers have moderate restriction and 23 workers have severe restriction. Hence it is concluded that yearly assessment of pulmonary function is necessary for evaluation of the respiratory risk from carbon black and chromium dust environment to plan further preventive intervention.

Authors and Affiliations

Dr. Panneerselvam, T. , Dr. Kumudha, P. , Dr. Vishnu Priya M. and Dr. Sangeetha, K. P.

Keywords

Related Articles

Comparative evaluation of efficacy of three different retreatment regimens in gutta-percha removal with and without chloroform – An in vitro study

Background: A growing interest in endodontic retreatment has been seen recently to preserve teeth where endodontic therapy has failed. Effective removal of gutta-percha in endodontic retreatment is a significant factor t...

Malaria in pregnancy: effect on maternal and fetal outcome in north-west rajasthan

Background & Objective: Malaria infection during pregnancy is a significant public health problem with substantial risks for the pregnant woman, her foetus, and the newborn child. So we conducted this study to predict th...

A unilateral variant of musculocutaneous nerve-case report

The fracture of distal third of arm is common in the surgical procedure. The Musculocutaneous (MCN) nerve which supply the arm is very important for various surgical procedures,and which shows the frequent variation.But...

A Comparative Study Of Salivary Parameters And Caries Index In Pregnant And Non Pregnant Women

Introduction: As a systemic condition, pregnancy causes changes in the functioning of the human body as a whole and specifically in the oral cavity; these changes may favour the emergence of diseases, such as dental cari...

Ultrasound elastography evaluation of breast masses with fnac and/or histopathological correlation

Background & Objectives: Ultrasound elastography is a non-invasive method for determining tissue mechanical properties. The aims of were to study: 1. The sensitivity and specificity of ultrasound elastography in the dete...

Download PDF file
  • EP ID EP405113
  • DOI -
  • Views 123
  • Downloads 0

How To Cite

Dr. Panneerselvam, T. , Dr. Kumudha, P. , Dr. Vishnu Priya M. and Dr. Sangeetha, K. P. (2016). Pulmonary function tests in stainlesssteel utensil polish workers-a cross sectional study. INTERNATIONAL JOURNAL OF CURRENT RESEARCH, 8(7), 34213-34220. https://europub.co.uk/articles/-A-405113