QUALITY INDICATORS ARE EFFECTIVE TO MONITOR THE PERFORMANCE LEVEL OF PREANALYTICAL PHASE- A STUDY IN A CLINICAL LABORATORY OF EASTERN INDIA

Journal Title: Journal of Evidence Based Medicine and Healthcare - Year 2018, Vol 5, Issue 13

Abstract

BACKGROUND In clinical laboratories, establishment and monitoring of multiple Quality Indicators in preanalytical phase to cut down the error rate has a promising role in Quality Assurance. MATERIALS AND METHODS The total pathway of preanalytical phase was traced to evaluate various Quality Indicators already established by International Federation of Clinical Chemistry (IFCC) and Laboratory Medicine Working Group on Laboratory Errors and Patient Safety (WGLEPS), among them, we monitored QI-5 (Requests with errors concerning patient identification), QI-7 (Requests with errors concerning test input), QI-8 (Samples lost-not received), QI-9 (Samples collected in inappropriate container), QI-10 (Haemolysed samples), QI-12 (Samples with insufficient sample volume) and QI-15 (Improperly labelled samples). RESULTS During 1 year of study period, a total no of 108000 samples were received in the Clinical Biochemistry laboratory. Total preanalytical errors recorded was 277 (0.25% of the total number of samples). Among them, patient identification error was 11.1%, missing test inputs was 4.3%, 49% were haemolysed, 10.1% were not received in the laboratory, 5% were collected in wrong container, 11.9% samples showed inadequate sample to anticoagulant ratio and 8.3% of samples were improperly labelled. The results were compared with specifications of IFCC (WG-LEPS). All the evaluated QIs were found to be within optimal level. Sigma values also were within acceptable range. CONCLUSION The performance in preanalytical phase of our laboratory was found favourable and complies with international quality specifications.

Authors and Affiliations

Aritri Bir, Arindam Ghosh, Sulekha Sinha, Arindom Banerjee

Keywords

Related Articles

EARLY PRESENTATION OF LESS COMMON ASSOCIATION- SYSTEMIC SCLEROSIS WITH APLA

PRESENTATION OF CASE A 25-year-old female presented to outpatient department with complaints of pain in small joints of hand and on exposure to cold water since 2 months. Patient was nonsmoker and nonalcoholic. Patient w...

ANALYTICAL STUDY OF PSEUDOEXFOLIATION SYNDROME, ITS ASSOCIATION WITH GLAUCOMA AND ITS SURGICAL COMPLICATIONS

BACKGROUND Pseudoexfoliation syndrome is commonly associated with Glaucoma. Surgical complications occur frequently in this clinical setting, the incidence of which needs to be analysed. MATERIALS AND METHODS 100 patient...

STUDY OF CONTACT SENSITIZATION AND ITS PATTERN IN PATIENTS OF HAND ECZEMA

BACKGROUND Hand eczema is a common problem with multifactorial etiology. Both endogenous factors like atopy, stress and exogenous factors like contact with irritants and allergens have been incriminated in its causation...

OBJECTIVE STRUCTURED PRACTICAL EXAMINATION AS AN ASSESSMENT TOOL IN PHYSIOLOGY

BACKGROUND Assessment is the process by which the teacher and the student gain knowledge about student progress. The conventional practical examination is beset with several problems. The Objective Structured Practical E...

ROLE OF DOPPLER EVALUATION OF THYROID GLAND IN DIFFERENTIATING GRAVES’ DISEASE FROM OTHER THYROTOXIC STATES

BACKGROUND Differentiation between thyroiditis induced thyrotoxicosis and Graves' disease is needed for selection of proper therapy. It is often difficult to differentiate between them without performing thyroid scintigr...

Download PDF file
  • EP ID EP541098
  • DOI 10.18410/jebmh/2018/236
  • Views 66
  • Downloads 0

How To Cite

Aritri Bir, Arindam Ghosh, Sulekha Sinha, Arindom Banerjee (2018). QUALITY INDICATORS ARE EFFECTIVE TO MONITOR THE PERFORMANCE LEVEL OF PREANALYTICAL PHASE- A STUDY IN A CLINICAL LABORATORY OF EASTERN INDIA. Journal of Evidence Based Medicine and Healthcare, 5(13), 1140-1145. https://europub.co.uk/articles/-A-541098