Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process

Journal Title: Chinese Journal of Blood Transfusion - Year 2024, Vol 37, Issue 3

Abstract

Objective To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. Methods A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. Results The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). Conclusion The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

Authors and Affiliations

Yuqing WU, Hong ZHOU, Zhijie ZHANG, Zhiquan RONG, Xuemei LI, Zhe SONG, Shuhong ZHAO, Zhongsi YANG, Qun LIU, Lin ZHU, Xiaojuan FAN, Shuli SUN, Wei ZHANG, Jinyu HAN, Haiyan HUANG, Guangcai LIU, Ping CHEN, Xianwu AN, Hui ZHANG, Junxia REN, Xuejing LI, Chenxi YANG, Bo ZHOU, Hui YE, Mingming QIAO, Hua SHEN, Dunzhu GONGJUE, Yunlong ZHUANG

Keywords

Related Articles

Establishment and clinical application of Kidd, Diego, Duffy blood group system, Shaanxi Province

Objective To screen individuals with rare blood type of Kidd, Diego, Duffy blood group system among the voluntary blood donor in Shaanxi province and to establish on-line and physical database of rare blood type. Methods...

Analysis of ABO gene mRNA expression in peripheral blood of patients with acute myeloid leukemia

Objective To investigate the expression characteristics of ABO gene mRNA in peripheral blood of patients with acute myeloid leukemia. Methods The RNA-seq data of acute myeloid leukemia in TCGA database and the whole bloo...

Effects of intraoperative blood salvage on red blood cells

Intraoperative blood salvage (IBS) is a life support technology that uses a series of artificial devices to treat the recycled blood during surgery, which then is transfused back into the patients. Currently, it′s the ke...

Confidential unit exclusion in Guangzhou from 2009 to 2022

Objective To investigate the condition of confidential unit exclusion(CUE) in Guangzhou, so as to ensure blood safety. Methods The number of CUE donors, demographic characteristics of CUE donors, reasons for CUE, and res...

Analysis of HLA allele-specific antibodies and Eplets in patients with platelet transfusion refractoriness

Objective To analyze the specificity and Eplets of HLA allele-specific antibody in patients with platelet transfusion refractoriness (PTR). Methods HLA-A and B genotypes were detected by PCR-SBT, and HLA-Ⅰ antibodies in...

Download PDF file
  • EP ID EP738777
  • DOI 10.13303/j.cjbt.issn.1004­549x.2024.03.004
  • Views 3
  • Downloads 0

How To Cite

Yuqing WU, Hong ZHOU, Zhijie ZHANG, Zhiquan RONG, Xuemei LI, Zhe SONG, Shuhong ZHAO, Zhongsi YANG, Qun LIU, Lin ZHU, Xiaojuan FAN, Shuli SUN, Wei ZHANG, Jinyu HAN, Haiyan HUANG, Guangcai LIU, Ping CHEN, Xianwu AN, Hui ZHANG, Junxia REN, Xuejing LI, Chenxi YANG, Bo ZHOU, Hui YE, Mingming QIAO, Hua SHEN, Dunzhu GONGJUE, Yunlong ZHUANG (2024). Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process. Chinese Journal of Blood Transfusion, 37(3), -. https://europub.co.uk/articles/-A-738777