Rapid in vivo oral screening in rats: Reliability, acceptance criteria, and filtering efficiency

Journal Title: The AAPS Journal - Year 2006, Vol 8, Issue 3

Abstract

The reliability and acceptance criteria of rapid oral exposure screening were evaluated by pharmacokinetic simulations and by comparing oral exposure of 100 proprietary compounds from 15 therapeutic programs obtained at different times by cassette accelerated rapid rat screen (CARRS) and conventional pharmacokinetic (full-PK) procedures. Once acceptance criteria were established, the filtering efficiency (discard rate) was assessed with a larger data set of 5289 compounds tested by CARRS only. These evaluations indicated that area under the concentration-time curve during the first 6 hours (AUC6h) capture>50% of AUC∞ for most (71%) of the compounds and AUC6h from CARRS is comparable to AUC6h from full-PK in categorizing oral exposure as low, moderate, or high; therefore, the truncated AUC6h derived from pooled plasma samples is suitable for oral exposure screening. The CARRS profiles did not provide reliable half-life estimates; however, compounds with substantial AUC beyond 6 hours can be identified when (C6h/Cmax × 100%) exceeds 80%. Of interest, both the observed data and the simulated data indicated that AUC6h can be estimated using a single time point plasma concentration at 3 hours. The relationship between the maximum biovailability and AUC∞ over a range of clearane values was simulated. A threshold AUC (500 h*ng/mL) at the routine screening dose of 10 mg/kg was established below which a compound can be discarded. Examination of screening results for 5289 compounds evaluated over the last few years in our laboratory indicated that CARRS had a filtering efficiency of 50%, suggesting that this criterion provides a useful decision gate to avoid wasting the drug discovery resources on nonviable candidates.

Authors and Affiliations

Hong Mei, Walter Korfmacher, Richard Morrison

Keywords

Related Articles

The Interaction of Fatty Acid Amide Hydrolase (FAAH) Inhibitors with an Anandamide Carrier Protein Using 19F-NMR

It has been reported that the endocannabinoid anandamide (AEA) binds to a class of fatty acid-binding proteins and serum albumin which can serve as carrier proteins and potentiate the cellular uptake of AEA and its intra...

Opioid Tolerance Development: A Pharmacokinetic/Pharmacodynamic Perspective

The opioids are commonly used to treat acute and severe pain. Long-term opioid administration eventually reaches a dose ceiling that is attributable to the rapid onset of analgesic tolerance coupled with the slow develop...

Impact of antimicrobial resistance on regulatory policies in veterinary medicine: Status report

Increasing resistance to antimicrobial agents is of growing concern to public health officials worldwide. The concern includes infections acquired in hospitals, community infections acquired in outpatient care settings,...

Anionic liposomal delivery system for DNA transfection

The present study investigates the use of novel anionic lipoplexes composed of physiological components for plasmid DNA delivery into mammalian cells in vitro. Liposomes were prepared from mixtures of endogenously occurr...

An Extended Minimal Physiologically Based Pharmacokinetic Model: Evaluation of Type II Diabetes Mellitus and Diabetic Nephropathy on Human IgG Pharmacokinetics in Rats

Although many studies have evaluated the effects of type 2 diabetes mellitus (T2DM) on the pharmacokinetics (PK) of low molecular weight molecules, there is limited information regarding effects on monoclonal antibodies....

Download PDF file
  • EP ID EP681805
  • DOI  10.1208/aapsj080358
  • Views 66
  • Downloads 0

How To Cite

Hong Mei, Walter Korfmacher, Richard Morrison (2006). Rapid in vivo oral screening in rats: Reliability, acceptance criteria, and filtering efficiency. The AAPS Journal, 8(3), -. https://europub.co.uk/articles/-A-681805