RAPID, METHOD FOR DETERMINATION OF METFORMIN AND CANAGLIFLOZIN IN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETER, APPLICATION TO BIOEQUIVALENCE STUDY

Journal Title: Asian Journal of Pharamceutical and Clinical Research - Year 2019, Vol 12, Issue 2

Abstract

Objective: The objective of the study was to develop and validate a rapid selective bioanalytical method for the simultaneous determination of metformin and canagliflozin in plasma by liquid chromatography-tandem mass spectrometer (LC-MS/MS) to facilitate bioequivalence study sample analysis. Stock solutions and spiking solutions were prepared accurately in methanol and 80% methanol in water, respectively. Methods: Chromatography monitored using Analyst 1.6.2 software. Method was found selective, no matrix effect, reproducible and consistent recovery, accuracy, precision, and stable in aqueous as well as extracted/matrix samples. Method found linear over the range 10–2000 ng/ml for metformin and 30–6000 ng/ml for canagliflozin. The method is successfully applied to analyze samples collected in a bioequivalence study after administration of metformin/canagliflozin 1000/150 mg to 24 healthy male volunteers. Results: Extraction was carried out using a simple solid phase extraction using mobile phase elution. 5 μl sample delivered as injection volume in 1.000 ml/min isocratic mobile phase flow on turbo ion electron spray technique for positive mode on API 4000 MS. Discussion: Chromatography achieved within 3 min using a mobile phase containing acetonitrile and 10 mM ammonium formate buffer in a ratio of 70:30 on chromolith C18 analytical column. Q1/Q3 are 130.1/70.1, 136.3/77.1, 462.2/267.2 (with ammonium adduct), and 466.4/267.1 for metformin, metformin D6, canagliflozin, and canagliflozin D4, respectively. Conclusion: Rapid, sensitive method for the simultaneous estimation of metformin and canagliflozin in plasma by LC-MS/MS is successfully developed, validated and applied to analyze 960 unknown samples of a bioequivalence study. Incurred sample reanalysis was revealed great reproducibility.

Authors and Affiliations

SAMBASIVA RAO PURAM, NITHYA G, SUBBA RAO NB, RAMAN BATHEJA

Keywords

Related Articles

EVALUATION AND COMPARISON OF CYTOTOXIC EFFECT OF VILAZODONE HYDROCHLORIDE WITH 5-FLUOROURACIL IN HT-29 BOWEL CANCER CELL LINE

Objectives: Vilazodone hydrochloride is a novel selective serotonin reuptake inhibitor (SSRI) used to treat major depressive disorders. There are only sparse data available to know about the SSRI’s and its association wi...

COMPARISON OF THE EFFECTS OF NIGELLA SATIVA OIL AND LASER ON TREATMENTS ON EXPERIMENTAL WOUND HEALING IN RATS

Objective:The study investigated the influences of treatment with Nigella sativa oil and laser therapy on wound healing in rats. The period of the inflammatory phase reduced through both laser and N. sativa oil actions;...

COMPARATIVE INVESTIGATION OF TOTAL ANTIOXIDANT AND FREE RADICAL SCAVENGING ACTIVITIES OF TWO ALLIUM SPECIES

ABSTRACTObjective: The main intention of this study was to assess the comparative free radical scavenging and total antioxidant capacities (TAC) of freshAllium sativum (garlic) bulbs and Allium cepa cultivar (green onion...

N-ACETYLCYSTEINE, A BOON FOR YELLOW PHOSPHORUS-INDUCED ACUTE LIVER FAILURE? A CASE REPORT

Rat killer, in the form of a paste, is a commonly used rodenticide in India. It contains 3% yellow phosphorus, which is a local and a systemic toxin that damages all tissues it contacts. The lethal dose of yellow phospho...

SOLID DISPERSIONS: RESUSCITATING ORAL DELIVERY OF HYDROPHOBIC DRUGS

Objective: This review article explores solid dispersions (SDs) as one of the suitable approaches to formulate poorly water-soluble drugs. The objective of this review on SD techniques is to explore their utility as a fe...

Download PDF file
  • EP ID EP608739
  • DOI 10.22159/ajpcr.2019.v12i2.29027
  • Views 127
  • Downloads 0

How To Cite

SAMBASIVA RAO PURAM, NITHYA G, SUBBA RAO NB, RAMAN BATHEJA (2019). RAPID, METHOD FOR DETERMINATION OF METFORMIN AND CANAGLIFLOZIN IN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETER, APPLICATION TO BIOEQUIVALENCE STUDY. Asian Journal of Pharamceutical and Clinical Research, 12(2), 93-97. https://europub.co.uk/articles/-A-608739