Rapid Qualitative and Quantitative Analysis of Morphine in the Street and Biological Samples Using Densitometry Scan of Thin Layer Chromatography
Journal Title: Journal of Police Medicine - Year 2023, Vol 12, Issue 1
Abstract
Aims: In recent years, research in the field of identifying and quickly determining the amount of narcotics, including morphine, has grown significantly. This research aimed to provide a cheap, simple, and fast method for the quantitative identification of morphine in street samples and biological samples. Materials and Methods: This experimental research was conducted in the laboratory of the Narcotics Department of the Police University in the spring and summer of 2021. In this study, powder samples and urine samples containing morphine were tested to measure the amount of morphine by densitometry scan of TLC plates. Silica thin layer chromatography plates 60G F254 (Merck) and mobile phase including acetonitrile, methanol, and ammonia (1:2:17) for performing TLC tests, chloroform, and -2 propanol with a ratio of 9:1 for extraction, Camag TLC Scanner 3 device with software WinCATS 1.4.2.8121 were used for qualitative and quantitative analysis. RF values were obtained using the morphine standard (16.2 mm). Morphine standard solutions with a concentration of 500 μg/ml were made from the initial standard solution in methanol. For the calibration curve, 500 µg/ml standard solution from 2 to 12 µl was spotted on the chromatography paper to obtain a concentration range of 1-6 µg/spot of morphine. Each standard solution was spotted three times on the paper, and the calibration curve was drawn in terms of the average area with the inner peaks and different concentrations of standard spots (μg/spot). A good correlation was observed between the concentration of morphine and the peak. The regression equation y=4049.21+238.65x with a correlation coefficient of 0.9887 was obtained for the standard spotted sample (Figures 2 and 3). The accuracy of the TLC scanning method for the measurement of morphine was investigated by conducting reproducibility studies for three different concentrations in the linear range of the calibration curve and RSD of less than 6% was obtained with three repetitions (Table 1). Also, the accuracy of the TLC scan analysis method was checked by measuring the samples added with morphine in three different concentrations, and the recovery percentage was obtained from 96.9 to 104.5 (Table 2). The method's detection limit was calculated according to the slope of the calibration curve of 0.2 μg/spot. Investigations showed that the presence of codeine, acetaminophen, and caffeine in the samples does not interfere with the measurement of morphine because their bands are well separated from morphine on a thin layer of chromatography paper. A mixture of codeine, acetaminophen, and caffeine powder was used to prepare samples similar to street samples. Then morphine standard was used to add morphine with different concentrations to them. The samples were dissolved in methanol, and after making up to volume, they were again diluted with methanol to fall within the range of the calibration curve and the spotting, separation, and scanning steps were performed similarly to the standards. Finally, the amount of morphine was calculated according to the calibration curve and the dilution rate. The recovery rate of morphine for the added sample similar to the street sample was 95% with a standard deviation of 5.9%. Morphine measurement in urine sample: To measure morphine in the urine sample, samples were prepared in the concentration range of 400 to 600 ng/ml according to the mentioned method. The findings showed that the calibration curve with a correlation coefficient of 0.9796 shows an acceptable linear relationship between the concentration of morphine in standard samples and of that in the under-peak area related to morphine. The RSD for three replicates of the standard sample with a concentration of 500 ng/ml was less than 7%. The urine sample containing morphine (500 ng/ml) was calculated according to the test method of standard test samples and using the calibration curve based on which the recovery percentage was 94.6%, with a relative standard deviation of 5.8%. Conclusion: Densitometry scan of thin layer chromatography is a rapid and inexpensive screening method for the qualitative and quantitative analysis of morphine in the street and urine samples. Clinical & Practical Tips in POLICE MEDICINE: In this study, an attempt has been made to use the TLC densitometry technique for simple, cost-effective separation, capable of analyzing several samples simultaneously and in parallel that this technique, in addition to quick and simple detection (qualitative), can measure the amount of morphine (quantitative) in biological and police samples. Acknowledgments: The support of the president of Police University is gratefully acknowledged. Conflict of Interest: The article's authors stated that there is no conflict of interest regarding the present study. Authors Contribution: Asghar Eftekhari (idea presentation, data collection); Akram Ameli (study design and data analysis); Mohsen Babaei (data analysis); all the authors participated in the initial writing of the article and its revision, and with the final approval of this article, accept responsibility for the accuracy and correctness of the content contained in it. Funding Sources: The authors did not receive any financial support from public or private authorities.
Authors and Affiliations
Asghar Eftekhari1, Akram Ameli *2, Mohsen Babaei3 1- Department of Anti Narcotic, Faculty of Intelligence & Criminal Investigation Science & Technology, Amin Police University, Tehran, Iran 2- Department of Anti Narcotic, Faculty of Intelligence & Criminal Investigation Science & Technology, Amin Police University, Tehran, Iran , ameliakram90@gmail. com 3- Department of Identity Recognition & Medical Sciences, Faculty of Intelligence & Criminal Investigation Science & Technology, Amin Police University, Tehran, Iran
Designing and Psychometry of the Evaluation Checklist for the Registration and Labeling Guidelines of Anesthetic Drugs in the Operating Room
Aims: The correct registration and labeling of anesthetic drugs in the operating room are the basic and important principles in order to maintain patient safety, reduce the wastage of drugs and their subsequent costs, an...
Gene editing: biosecurity challenges and risks
INTRODUCTION and HISTORY of GENE EDITING After the first presentation of the term biotechnology by Karl Erky, a Hungarian agricultural engineer, perhaps few people imagined this technology would be used in offensive asp...
The mediating role of emotional expressiveness in the relationship between Hexaco personality traits with internet betrayal in students
Aims: According to the cognitive-behavioral approaches in family-related issues, personality and emotional factors play a significant role in the type of tendency of couples to infidelity. This research was conducted to...
Correlation between Functional-Movement Screening Test with Stature Abnormalities and Upper Limb Function of Military Personnel
Aims: Standard functional-movement screening tests can be one of the predictors of musculoskeletal injuries in military forces. This study aimed to investigate the relationship between functional-movement screening test...
Prediction of Addiction Readiness in Cancer Patients Based on the Perception of Social Support with the Mediation of Pain Self-Efficacy and Pain Acceptance
Aims: Cancer pain creates negative thoughts and beliefs in patients, which can affect the level of functioning and pain tolerance in these patients. In recent decades, the use of drugs for pain relief in cancer patients...