In this paper, a shunt active power filter (SAPF) based on adaptive hysteresis band current controller (HBCC) is proposed for limiting the harmonics in load current and also compensate the reactive power for 3 phase non-linear load. The HBCC calculate the active power and reactive power, transforms them in d, q and 0 components using Clarkes transformation then calculates the compensating values of active and reactive power to inject them further in system. The HBCC determines the switching signals of the SAPF, and the algorithm based on an extension of synchronous reference frame theory (d-q-0) is used to determine the suitable current reference signals. The results of simulation study of SAPF control technique presented in this paper is found quite satisfactory to eliminate harmonics and reactive power components from utility current. Zahid Hassan | Gagan Deep Yadav"Reactive Power Compensation and Limiting Harmonic Current using Shunt Active Power Filter" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-2 | Issue-4 , June 2018, URL: http://www.ijtsrd.com/papers/ijtsrd12958.pdf http://www.ijtsrd.com/engineering/electrical-engineering/12958/reactive-power-compensation-and-limiting-harmonic-current-using-shunt-active-power-filter/zahid-hassan

Authors and Affiliations

Keywords

Related Articles

Assessment of Sulphur Dioxide Levels in Selected Sites in Athi River, Kenya

Industrialization, economic growth, urbanization and population growth have been responsible for air pollution in developing countries. The discharge of harmful chemicals and increased combustion of fossil fuels, affect...

A Perspective Study of Warning Letters on Data Integrity Issued by FDA between 2017 and 2019

Data integrity credential is a good stride to the pharmaceutical industry and also helps for the prospective market growth of the industry by increasing the public trust, reputation. Data integrity is a head way for main...

Development of Concrete Filled Steel Tube CFST A Review

Concrete filled steel tube CFST structure offers numerous structural benefits, and has been widely used in civil engineering structures. This paper reviews the development of concrete filled steel tubular structures memb...

GC–MS Analysis of Bioactive Compounds Present in Ethanol Extract of Panicum Maximum Jacq Leaves

Phytoconstituents present in the ethanolic extract of Panicum maximum leaves were explored by Gas Chromatography Mass Spectrometry analysis. The compounds were identified by the gas chromatography coupled with the mass s...

Parallel between Comedy of Humours and Comedy of Manners

The comedy of humour which deals largely with exaggerated types of humour was one which adumbrated in the and in Ralph Roister Dolster and then after a not very glorious career was rendered popular by Jonson in Every Man...

Download PDF file
  • EP ID EP360990
  • DOI -
  • Views 80
  • Downloads 0

How To Cite

(2018). Reactive Power Compensation and Limiting Harmonic Current using Shunt Active Power Filter. International Journal of Trend in Scientific Research and Development, 2(4), -. https://europub.co.uk/articles/-A-360990