Reactive Power Compensation and Limiting Harmonic Current using Shunt Active Power Filter

Abstract

In this paper, a shunt active power filter (SAPF) based on adaptive hysteresis band current controller (HBCC) is proposed for limiting the harmonics in load current and also compensate the reactive power for 3 phase non-linear load. The HBCC calculate the active power and reactive power, transforms them in d, q and 0 components using Clarkes transformation then calculates the compensating values of active and reactive power to inject them further in system. The HBCC determines the switching signals of the SAPF, and the algorithm based on an extension of synchronous reference frame theory (d-q-0) is used to determine the suitable current reference signals. The results of simulation study of SAPF control technique presented in this paper is found quite satisfactory to eliminate harmonics and reactive power components from utility current. Zahid Hassan | Gagan Deep Yadav"Reactive Power Compensation and Limiting Harmonic Current using Shunt Active Power Filter" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-2 | Issue-4 , June 2018, URL: http://www.ijtsrd.com/papers/ijtsrd12958.pdf http://www.ijtsrd.com/engineering/electrical-engineering/12958/reactive-power-compensation-and-limiting-harmonic-current-using-shunt-active-power-filter/zahid-hassan

Authors and Affiliations

Keywords

Related Articles

Design and Construction of an Electric Arc Welding Machine's Transformer

Arc welding machine is the type machine that uses an electric power as an input, which is being supplied through the primary and then transferred to the secondary winding by induction which can be used to carry out weldi...

A Review Paper Study on Tall Structure for Hilly and Plane Surface under Seismic and Wind Load Conditions

Earthquakes occur when energy stored in elastically strained rocks is suddenly released. This release of energy causes severe ground shaking in the areas near the source of the earthquake and sends wave of elastic energy...

Experimental Study on Voided Biaxial Slab and its Application

Slab is largest member which consumes concrete. If the load acting on the slab is large or clear span between columns is more, the thickness of slab increases. It leads to consume more material such as concrete and steel...

Improvement in the process of Production Planning Applying the Simplex Method

The manufacture of metal-mechanical parts is very important in the industrial field. Due to the increasing demand in the market, the company under study decided to develop the application of this method, to be able to kn...

Review on Micro Electro Mechanical Systems

MEMS acronym for Micro Electro Mechanical System is one of the booming technology that has paved its way in current engineering and technology. This paper includes the explanation of simple MEMS system and its applicatio...

Download PDF file
  • EP ID EP360990
  • DOI -
  • Views 86
  • Downloads 0

How To Cite

(2018). Reactive Power Compensation and Limiting Harmonic Current using Shunt Active Power Filter. International Journal of Trend in Scientific Research and Development, 2(4), -. https://europub.co.uk/articles/-A-360990