Real-Time Implementation of an Open-Circuit Dc-Bus Capacitor Fault Diagnosis Method for a Three-Level NPC Rectifier

Abstract

The main goal of this paper is to detect the open-circuit fault of the electrolytic capacitors usually used in the dc-bus of a three phase/level NPC active rectifier. This phenomenon causes unavoidable overvoltage across the dc-bus leading therefore to the destruction of the converter’s power semiconductors. The real-time detection of this fault is therefore vital to avoid severe damage as well as wasted repair time. The proposed diagnosis method is based on the measurement of the voltages across the two dc-bus capacitors. Their mean values are therefore compared with the half value of the dc-bus reference voltage. If the comparison result is under a predefined threshold value, a fault alarm signal is generated in real-time by the monitoring system. The converter’s control algorithm and fault detection method are both implemented in real-time on a DSP controller. The obtained experimental results confirm the effectiveness of the proposed diagnosis technique. Indeed, a fault signal is generated at the peripheral of the DSP after 60 ms of the fault occurrence.

Authors and Affiliations

Fatma Ezzahra LAHOUAR, Mahmoud HAMOUDA, Jaleleddine BEN HADJ SLAMA

Keywords

Related Articles

Proposed an Adaptive Bitrate Algorithm based on Measuring Bandwidth and Video Buffer Occupancy for Providing Smoothly Video Streaming

Dynamic adaptive streaming via HTTP (DASH) has been popular disseminated over the Internet especially under the circumstances of the time varying network, which it is currently the most challenging for providing smoothly...

A Comparative Analysis of Wavelet Families for the Classification of Finger Motions

Wavelet transform (WT) has been widely used in biomedical, rehabilitation and engineering applications. Due to the natural characteristic of WT, its performance is mostly depending on the selection of mother wavelet func...

A Secure Cloud Computing Architecture Using Homomorphic Encryption

The Purpose of homomorphic encryption is to ensure privacy of data in communication, storage or in use by processes with mechanisms similar to conventional cryptography, but with added capabilities of computing over encr...

Modified Hierarchical Method for Task Scheduling in Grid Systems

This study aims to increase the productivity of grid systems by an improved scheduling method. A brief overview and analysis of the main scheduling methods in grid systems are presented. A method for increasing efficienc...

Design and Simulation of a Low-Voltage Low-Offset Operational Amplifier

In many applications, offset of the OP-AMPs should be canceled to high accuracy be accomplished. In this work, an asymmetrical differential input circuit with active DC offset rejection circuit was implemented to minimiz...

Download PDF file
  • EP ID EP396960
  • DOI 10.14569/IJACSA.2016.071131
  • Views 73
  • Downloads 0

How To Cite

Fatma Ezzahra LAHOUAR, Mahmoud HAMOUDA, Jaleleddine BEN HADJ SLAMA (2016). Real-Time Implementation of an Open-Circuit Dc-Bus Capacitor Fault Diagnosis Method for a Three-Level NPC Rectifier. International Journal of Advanced Computer Science & Applications, 7(11), 243-247. https://europub.co.uk/articles/-A-396960