Receive Bandwidth Variation Effect Toward the Signal and Contrast to Noise Ratio in Magnetic Resonance Imaging (MRI) Cervical Examination with the Sequence of T1 Weighted Turbo Spin Echo

Journal Title: Journal of Medical Science And clinical Research - Year 2017, Vol 5, Issue 7

Abstract

Introduction: The received bandwidth parameter is a parameter affecting the value of Signal to Noise Ratio (SNR) where the radiographer is usually stuck to the existing protocol: the bandwidth of 146 Hz /Px. In fact, by doing the variation of received bandwidth, the pictures of SNR variation will be obtained to define the best bandwidth to SNR and contrast to noise ratio (CNR). Objective: The purpose of this research is to find out the effect of received bandwidth variation on SNR and CNR and to determine the most optimal received bandwidth for SNR and CNR on cervical MRI with the sequence of T1 Weighted Turbo Spin Echo (TSE) in the sagittal slice. Methods: The type of this research is quantitative research with experimental approach done with MRI 1.5 Tesla at General Hospital Dr. Hasan Sadikin Bandung. The data were 35 cervical TRL images of TSE in the sagittal slice from 7 probands with 5 received bandwidth variations (106 Hz / Px, 126 Hz / Px, 146 Hz / Px, 166 Hz / Px and 186 Hz / Px). To obtain SNR and CNR values, an area of interest (ROI) measurement is performed on the corpus, discus, spinal cord and CSF regions to obtain the average signal and compared with the standard deviation value of the background. Data was analyzed with linear regression and descriptive mean rank test. Result: The result of the research shows the effect of received bandwidth on SNR and CNR on MRI cervical. There is a strong correlation between received bandwidth variation with cervical SNR with correlation coefficient = 0.639, and there is a moderate correlation between received bandwidth variation with CNR cervical with correlation coefficient = 0,532 with p - value < 0.05. The optimal received bandwidth value of the T1WI saturation T1WI T1WI MRI is 106 Hx / px with a mean rank of SNR = 160.5 and mean rank of CNR = 76.59. Conclusion: The received bandwidth variations on SNR and CNR in MRI significantly affect the cervical examination. The optimal received bandwidth value of T1WI TSE in the sagittal slice is 106 Hx / px.

Authors and Affiliations

Retno Wati

Keywords

Related Articles

Awareness of Biomedical Waste Management among MBBS Students at a Tertiary Care Teaching Hospital in Mewat, Haryana

Introduction: Biomedical waste is any waste, which is generated during the diagnosis, treatment or immunization of human beings or in research activities or in the production or testing of biological products. Biomedical...

Comparison of Scoring Systems for Mortality Prediction in Acute Exacerbation of Chronic Obstructive Pulmonary Disease

Acute exacerbation of chronic obstructive pulmonary disease (AECOPD) is a frequent cause of emergency admission. A scoring system is invaluable in predicting mortality and guiding therapeutic interventions. Aims: Compari...

Correlation of Glycated Albumin Levels with Serum Adenosine Deaminase in type 2 Diabetes Patients

Background: In recent times Glycated Albumin routinely using as glycemic parameter to asses the status of diabetes complications. Type 2 diabetes mainly due to shortage or scarcity of insulin secretion. This insulin secr...

To Determine the Efficacy of Neural Mobilization in Reducing Pain and Increasing Functional Ability in Patients with Cervical Radiculopathy

Need and Purpose- To find out the efficacy of neural mobilization in reducing pain and increasing functional ability in patients with cervical radiculopathy. Study Design- random sampling Participant’s 30 subjects recrui...

Pain Relief after Arthroscopic Knee Surgery- Intra-Articular Dexmedetomidine and Fentanyl: A Randomized Control Study

Background: No single ideal intra-articular drug has been found for postoperative pain management which is a common and distressing symptom after knee arthroscopy. This study was done to study the efficacy of intraarticu...

Download PDF file
  • EP ID EP490274
  • DOI -
  • Views 48
  • Downloads 0

How To Cite

Retno Wati (2017). Receive Bandwidth Variation Effect Toward the Signal and Contrast to Noise Ratio in Magnetic Resonance Imaging (MRI) Cervical Examination with the Sequence of T1 Weighted Turbo Spin Echo. Journal of Medical Science And clinical Research, 5(7), 24313-24318. https://europub.co.uk/articles/-A-490274