Reconstruction with Composite Cement-Autoclaved Autograft after a Near-Total Excision of the Humerus for Osteosarcoma: A Case Report

Journal Title: Malaysian Orthopaedic Journal - Year 2009, Vol 3, Issue 2

Abstract

Osteosarcoma occurring in the humerus is often confined to the proximal part, in which case, reconstruction after excision is less daunting. When the tumour spreads down the medullary cavity distally, a total humeral replacement is often required. This is costly and beyond the means of the average patient in a developing country. An amputation is often the procedure of first resort. We report a 13-year-old boy with osteosarcoma originating from the left proximal humerus, with involvement of the marrow reaching down to the distal diaphyseal-metaphyseal junction, leaving only 6 cm of the distal humerus intact after wide resection. Reconstruction of the defect was done with a composite cement-autoclaved autograft fixed to the remaining humerus with a plate. At 40 months of follow-up, the patient is well with normal function of the elbow, wrist and hand. Salvaging the limb despite near total involvement of the humerus by high grade osteosarcoma is possible using material available in the average orthopaedic operating room.

Authors and Affiliations

KL Pan, A Zolqarnain, GB Ong

Keywords

Related Articles

Dupuytren Contracture in a Patient with Congenital Camptodactyly and Incidental Carpal Tunnel Syndrome

Dupuytren contracture is commonly seen in northern European populations but not in Asians. Even more rare is a presentation of flexion deformity of fingers involving two different pathologies with incidental carpal tunne...

Open Reduction and Internal Fixation of displaced Supracondylar Fractures of Humerus with Crossed K-wires via Medial Approach

This study aimed at evaluating the medial approach for open reduction and internal fixation of Gartland type 3 displaced supracondylar fractures of humerus in children. A prospective, single centre study of on displaced...

Plagiarism: The Bane of Publishing

Plagiarism - derived from the Latin word plagiarus which means “kidnapper”(1), is defined as the practice of taking ideas from someone else without citing the source. Plagiarism in the region is documented - in 2008 the...

A Preliminary Study of Human Amniotic Membrane as a Potential Chondrocyte Carrier

Purpose: To investigate the feasibility of using processed human amniotic membrane (HAM) to support the attachment and proliferation of chondrocytes in vitro which in turn can be utilised as a cell delivery vehicle in ti...

Outcome of Surgery for Unstable Intertrochanteric Fractures in Octogenarians

This study aims to determine pre-morbid parameters as possible predictors of outcome of hip fracture in octogenarians with unstable intertrochanteric fracture treated operatively. Presence of co-morbidities, pre-injury l...

Download PDF file
  • EP ID EP299391
  • DOI -
  • Views 95
  • Downloads 0

How To Cite

KL Pan, A Zolqarnain, GB Ong (2009). Reconstruction with Composite Cement-Autoclaved Autograft after a Near-Total Excision of the Humerus for Osteosarcoma: A Case Report. Malaysian Orthopaedic Journal, 3(2), 55-57. https://europub.co.uk/articles/-A-299391