Abstract

The article discusses the individual fire risk and how to reduce it. The necessity of creating a system of evacuation of the building in case of fire, which will reduce the risk of fire. The model of foot traffic in the building, which gives a minimum time of evacuation of the building - RINTD-Evac. The results of testing the model and comparing it with the Pathfinder and FDS + Evac. Presented by the use of software RINTD-Evac to design restrictions that are intended to reduce fire risk in the individual buildings.

Authors and Affiliations

V. Kolodkin, B. Chirkov

Keywords

Related Articles

ABOUT EFFECTIVE DURATION OF PROCESS OF STEAM FORMATION AT BOILING OF A LIQUID FROM PASSAGE

In article effective standards and rules on possibility of their use are analysed at calculation of effective duration of boiling of a liquid from passage. Conditions of course of processes of boiling and evaporation hav...

CANCEROGENIC RISK OF NITRATE CONTAMINATION OF WATER ECOSYSTEMS

Nitrate contamination of water ecosystems of the Chelyabinsk and its vicinities by the content analysis of these substance in underground, surface and rainwater, hydrophytes and bottom sediments is estimated. The nitrate...

APPLICATION OF RISK ANALYSIS METHODOLOGY FOR PREDICTING THE IMPACT OF OBJECTS OF PAST ENVIRONMENTAL DAMAGE ON THE ENVIRONMENT

A large number of objects of past environmental damage formed on the territory of the Russian Federation as a result of unsustainable economic activity. According to various estimates, the total area of polluted areas is...

Cost of statistical life and cost of risk

The question of estimating the value of the average human life in order her, the higher the risks. Today we are talking on this topic with the chief editor. of the journal Andrey Aleksandrovich Bykov, Doctor of Physics a...

Results of system and dynamic modeling of process of informing the population at chemical accident

In the previous article the system and dynamic model of informing the population during an accident is given in chemically dangerous object by means of services of cellular communication. The results of modeling actions...

Download PDF file
  • EP ID EP610907
  • DOI 10.32686/1812-5220-2016-13-1-52-59
  • Views 181
  • Downloads 0

How To Cite

V. Kolodkin, B. Chirkov (2016). Reduced fire risk in buildings crowded with people. Научно-практический журнал "Проблемы анализа риска", 13(1), 52-59. https://europub.co.uk/articles/-A-610907