Abstract

Wind power has become the most important renewable energy source. Two factors are mainly influencing its future development: scarcity of sites and levelized cost of energy (LCoE). By a site specific turbine and wind park design it is possible to improve both aspects compared to state of the art approach. Within this paper an analytical tool and a multi-objective optimization method is presented which is able to identify optimal site specific wind turbine and wind farm layout such that available space is used efficiently in terms of the amount of supplied energy and LCoE. With the help of this approach it is possible to increase a wind farms AEP by 20% and decrease its LCoE by 10% for an exemplarily site and wind park layout in Germany.

Authors and Affiliations

B Roscher1 ,, F Harzendorf, R Schelenz1 ,, G Jacobs

Keywords

Related Articles

Evaluation of Performance of an Indigenous Bambaranut Decorticating Machine

The performance of an indigenous Bambara groundnut decorticating machine was tested to make optimal use of locally developed decorticators as substitute for imported bambaranut decorticators. The test was based on the th...

Optimization of Pid Controler In Temperature Control System Processes Pasteurization of Milk

Pasteurization is one of the heating process done on fresh milk so it becomes a product that has a longer shelf life. By controlling the temperature in the pasteurization process is expected to be able to kill pathogenic...

Determination of Power Flow in PQ Bus System By Using Gauss Seidel Method

Power flow analysis is the backbone of power system analysis and design. They are necessary for planning, operation, economic scheduling and exchange of power between utilities. The principal information of power flow an...

Performance Improvement of a Petroleum Refining Process Using Quality Control

This study was aimed at applying Quality Control techniques in improving the performance of the production process in a Petroleum Refinery. Multiple Linear Regression analysis was employed to develop a Quality Control ma...

Download PDF file
  • EP ID EP396828
  • DOI -
  • Views 50
  • Downloads 0

How To Cite

B Roscher1, , F Harzendorf, R Schelenz1, , G Jacobs (2018). Reduced Levelized Cost ofEnergythrough Optimization of Tower Height, Rotor Diameter And\Wind Farm Layout. American journal of Engineering Research, 7(4), 130-138. https://europub.co.uk/articles/-A-396828