Reducing And Analysizing of Flow Accelerated Corrosion at Thermal Power Plant, Heat Recovery Steam Generators

Abstract

ABSTRACT The purpose of this study is to Reducing and Analysing of Flow Accelerated Corrosion in Thermal Plant Heat Recovery Steam Generators. All these studies have been performed in a new and 16 year-old established Combined Cycle Power Plants in Turkey. Corrosion cases have been investigated due to Mechanical Outage Reports at Power Plant in 2011-2015. Flow Accelerated Corrosion study has been based on specific zone related with Economizer Low Pressure connection pipings. It was issued a performance report. Results and lessons learnt from these studies will be used as a preventive action manner in all similar Plants.

Authors and Affiliations

Akın Avşaroğlu, Suphi URAL

Keywords

Related Articles

Design And Analysis of Fibre Reinforced Composite Ceiling Fan Blade

With the increasing energy crisis in the present and future generations facing in the society, there is a need to reduce and optimize the energy. Though wide range of researches is being done in the areas of alternate en...

A MBSE Approach for the Development of Complex Technical Systems

Model–-based development techniques have been successfully introduced into the design process of aircraft systems. Examples of these techniques are performance models for digital systems and networks or 3D–models for equ...

Improvement of the Recognition Rate by Random Forest

In this paper; we introduce a system of automatic recognition of characters based on the Random Forest Method in non-constrictive pictures that are stemmed from the terminals Mobile phone. After doing some pretreatments...

Highly Deformable Energy-Dissipating Reinforced Concrete Elements in Seismic Design of Reinforced Concrete Structures

Incorporating scrap tyre rubber particles as partial replacement for aggregates has been found to produce concrete with improved ductility, deformability and damping which are desired characteristics of a viable material...

Drought Index Analizes With Rainfall Patern Indicators Use SPI Method (Case Study Bangga Watershed)

Irregular weather and climate changes caused by El – Nino effect drought in some areas, including in Indonesia. The location of this study lies in the Bangga watershed. The purpose of this study was to determine rainfall...

Download PDF file
  • EP ID EP389713
  • DOI 10.9790/9622-0701022229.
  • Views 169
  • Downloads 0

How To Cite

Akın Avşaroğlu, Suphi URAL (2017). Reducing And Analysizing of Flow Accelerated Corrosion at Thermal Power Plant, Heat Recovery Steam Generators. International Journal of engineering Research and Applications, 7(1), 22-29. https://europub.co.uk/articles/-A-389713