RELIABILITY ANALYSIS OF 20 KV MEDIUM VOLTAGE AIR LINE DISTRIBUTION SYSTEM AT SEMANGGA SWITCH SUBSTATION IN MERAUKE REGENCY

Journal Title: Engineering and Technology Journal - Year 2022, Vol 7, Issue 10

Abstract

The breakdown of electrical energy can be caused by the unwanted failures that occur in the electric power system, especially in the distribution system, and have an impact on service continuity which can be a permanent failure, temporary failure, three phase short circuit failure, double phase short circuit failure, and black out. To anticipate this, a study needs to be done to analyze and find out how well the distribution system reliability index. Determination of the analysis was done by the method of data retrieval related to the analysis variable. Besides, in determining the results of the analysis, calculations using System Average Interruption Frequency Index (SAIFI), Customer Interruption Frequency Index (CAIFI), System Average Interruption Duration Index (SAIDI) and Customer Average Interruption Duration Index (CAIDI) analyses were performed. Based on the reliability of the distribution network, the SAIFI and CAIDI maximum threshold value setup by PT. PLN (The National Electricity Company) at the Semangga substation each worth 3.00 failures/customer.year and 3.00 failures/customerr while SAIDI and CAIDI each worth value of 3.40 hours/customer.year and 3.40 hours/customer.failure. All feeders installed at Semangga switch substation in realization gives reliability indices smaller than the target that has been set., it is mean that 20 kV medium voltage air line distribution system at Semangga switch substation still reliable and the duration of the failure time for each feeder was an average of 3 minutes of each failure and the number of failures every month was an average of 15 times of each feeder.

Authors and Affiliations

Paulus Mangera   Damis Hardianton   Daniel Parenden

Keywords

Related Articles

Static, Rigid Dynamics and Computational Fluid Dynamic Simulation of a Zero Co2 and Zero Heat Pollution Compressed Air Engine for the Urban Transport Sector

This article presents major findings created during a research work for sustainable solutions towards the ozone layer depletion and global warming in the name of modeling and simulating a zero CO2 and zero heat pollution...

DYNAMIC CELLULAR MANUFACTURING SYSTEMS AND THEIR SOLUTION USING GENETIC ALGORITHM

Production planning and cell formation problems are two important parts of this system, which have mutual effects. In this work, a comprehensive, non-linear mathematical model with integer variables has been proposed for...

Developing Laboratory Experiments to teach Undergraduate Engineering Students Multi-User Massive MIMO Technology for 5G Cellular Networks

An effective method of facilitating student learning in a laboratory environment is “practice by doing”. The study of modules related to signal-processing for digital communications requires deep mathematical and theoret...

Systematic Review of AI-Augmented Refactoring and Code Validation Tools in Aviation Technology Platforms

As aviation technology platforms become increasingly complex and software-intensive, ensuring code quality, maintainability, and compliance with stringent safety standards has become a critical priority. This systematic...

Automated Detection and Classification of Tomato Leaf Diseases Using Convolutional Neural Networks

Tomato (Solanum lycopersicum) is one of the most important vegetable crops globally, but its production is significantly affected by various foliar diseases such as Early Blight, Late Blight, and Septoria Leaf Spot. Time...

Download PDF file
  • EP ID EP716520
  • DOI 10.47191/etj/v7i10.04
  • Views 63
  • Downloads 0

How To Cite

Paulus Mangera   Damis Hardianton   Daniel Parenden (2022). RELIABILITY ANALYSIS OF 20 KV MEDIUM VOLTAGE AIR LINE DISTRIBUTION SYSTEM AT SEMANGGA SWITCH SUBSTATION IN MERAUKE REGENCY. Engineering and Technology Journal, 7(10), -. https://europub.co.uk/articles/-A-716520