RELIABILITY AND MINIMAL DETECTABLE CHANGE OF SIT-TO-STAND KINEMATICS AND KINETICS IN TYPICAL CHILDREN

Journal Title: Human Movement - Year 2018, Vol 19, Issue 3

Abstract

Purpose. The study aimed to determine the within- and between-session reliabilities as well as the minimal detectable change (MDC) of generally used temporal, kinematic, and kinetic parameters during the sit-to-stand (STS) task in typical children. Methods. The study involved 10 typical children (9.8 ± 1.6 years old). Motion analysis and force plate systems were used to collect markers for 3-dimensional trajectories in space and measure the ground reaction force. The total of 29 reflective markers were placed on each participant’s body in accordance with the Helen Hays marker set model by 1 rater on 2 separate days within the span of 1 week. Each subject was asked to perform an STS task 3 times from a height-adjustable chair. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and MDC for temporal, kinematic, and kinetic parameters were calculated within and between sessions. Results. The results indicated that the temporal parameters achieved excellent (ICC > 0.75), the kinematic parameters presented poor to excellent (0.232 < ICC < 0.997), and the kinetic parameters showed fair to excellent (0.635 < ICC < 0.977) reliabilities in both within- and between-session analyses. The SEM of most kinematic parameters was less than 2° both within and between sessions. In addition, the MDC values for between sessions ranged 1.25–12.64°. Conclusions. The findings support the reliability of using 3-dimensional motion analysis and force plate systems for measuring temporal, kinematic, and kinetic parameters for STS tasks in typical children. Key words: reliability, minimal detectable change, children, sit-to-stand, kinematics, kinetics

Authors and Affiliations

DUANGPORN SURIYAAMARIT, SUJITRA BOONYONG

Keywords

Related Articles

INTRA- AND INTER-EXAMINER RELIABILITY IN ANGULAR MEASUREMENTS OF THE KNEE WITH A SMARTPHONE APPLICATION

Purpose. Goniometric smartphone applications to measure joint angles offer greater practicality and accessibility, which makes them potential alternatives to a conventional goniometer. The aim of the present study was to...

Effects of an eleven-week Pilates exercise program on progressive-speeed walking capacity in sedentary young women: a pilot study

Purpose. To assess the effects of an 11-week Pilates exercise program on the functional capacity of young sedentary women. Methods. Ten subjects underwent the shuttle walking test. A portable metabolic system was used du...

Excessive TV viewing time and associated factors in Brazilian adolescents from a rural area&nbsp;

Purpose. Sedentary behavior has been identified as a risk factor for chronic non-communicable diseases. This study identified the prevalence of excessive TV viewing time during the week and weekend and associated factors...

&nbsp;Corporeality in martial arts anthropology

The aim of this paper is to discuss the subject as well as the problem of corporeality in the anthropology of martial arts. The authors wish to begin with the concept of corporeality as it is found in the available liter...

Agreement between body mass index and the sum of skinfolds in adolescents with different levels of physical activity

Purpose. The purpose of this study was to examine the agreement between body mass index and body fat estimate among adolescents with different physical activity (PA) levels, using the sum of skinfolds as our criterion. M...

Download PDF file
  • EP ID EP333015
  • DOI 10.5114/hm.2018.76079
  • Views 86
  • Downloads 0

How To Cite

DUANGPORN SURIYAAMARIT, SUJITRA BOONYONG (2018). RELIABILITY AND MINIMAL DETECTABLE CHANGE OF SIT-TO-STAND KINEMATICS AND KINETICS IN TYPICAL CHILDREN. Human Movement, 19(3), 48-54. https://europub.co.uk/articles/-A-333015