Reliability Assessment of Electrical Energy Distribution System – A Case Study of Port Harcourt Distribution Network

Abstract

This Paper Presents the Reliability Assessment of Electrical Energy Distribution System in Port Harcourt using the Analytical Technique and ETAP software as the simulation tool to run the reliability assessment of the System. The analysis was carried out using 2014 and 2015 historical data of Secretariat, Silver Bird, Water Works, UST and School of Nursing Injection Substations obtained from the Port Harcourt Electricity Distribution Company[PHEDC]. The results of the analysis revealed that Secretariat Injection Substation is the most reliable in the network when compared to the other four substations as it recorded system indices of ASAI: 99.90, SAIFI: 0.877, SAIDI: 8.11, CAIDI: 9.25 in 2014 and ASAI: 99.91, SAIFI: 0.873, SAIDI: 8.13, CAIDI: 9.14 in 2015. However, the overall reliability indices of the five substations under review as obtained from the analysis, revealed that the reliability of the distribution system is far below the set benchmark. System re-configuration and introduction of Photovoltaic Systems to re- supply interrupted loads at a shorter time are therefore recommended.

Authors and Affiliations

Fabian C. Oreke, D. C Idoniboyeobu

Keywords

Related Articles

Adaptive Image Equalization for Contrast Enhancement

The image equalization is used in this paper which automatically enhanced the contrast in an input image. To model the gravy level distribution of an image the Gaussian mixture model is used. In this model to partition...

Warning Tweet: A Detection System for Suspicious URLs in Twitter Stream

Twitter is a social networking site where users can exchange messages to other users particularly their followers. Usually the messages sent over twitter are known as tweets. Users can sent messages or tweets to users w...

Vapor−Liquid Equilibrium Data for the Binary System of Ethylene Glycol with Butanol At 94, 50, 10 KPA

Vapor−liquid equilibrium (VLE) data for Ethylene Glycol with Butanol are measured at pressure of 94, 50, 10 kPa by using a dynamic recirculation still. The experimental VLE data were tested to be thermodynamically consi...

Sign Language Recognition for Deaf Sign User

Sign language recognition is one of the most growing fields of research today and it is the most natural way of communication for the people with hearing problems. A hand gesture recognition system can provide an opport...

Enhancing the Android Mobile App Security using SHA-512 Algorithm

Nowadays most of the smart phones are using Android Operating System. Everyday millions of people are purchasing products using Android mobile App. But smart phone users are very much concerned about the security in Int...

Download PDF file
  • EP ID EP24449
  • DOI -
  • Views 341
  • Downloads 10

How To Cite

Fabian C. Oreke, D. C Idoniboyeobu (2017). Reliability Assessment of Electrical Energy Distribution System – A Case Study of Port Harcourt Distribution Network. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 5(6), -. https://europub.co.uk/articles/-A-24449