Abstract

Background: Electrolyte and blood gas analysis are essential for most patients who are admitted in the casualty. Routinely simultaneous arterial and venous sample would be sent to the laboratory for blood gas analysis and serum electrolytes respectively. Electrolytes can also be measured by the blood gas analyzer. We wanted to find out if these values were reliable. Methods: This study has been checked and permitted by the hospital ethics committee. We obtained two samples, one venous and one arterial sample from patients in the intensive care unit (ICU) and casualty of Ashwini rural medical college, hospital and research centre, (ARMCH&RC) Kumbhari Solapur. The arterial blood samples were analyzed on the ABOTT arterial blood gas analyzer (ABG) and venous samples were analyzed on PROLYTE electrolyte autoanalyzer (AA). Both instruments were placed in our biochemistry laboratory. Results: A total of 200 samples were analyzed. The mean ABG sodium value was 132.0 mmol/L (SD 9.82) and the mean AA sodium (Na+) was 135.7 mmol/L (SD 9.99). The mean AA sodium value was more than mean ABG sodium but statistically significant difference was not found (p=0.18). The mean ABG potassium (K+ ) value was 3.4 mmol/L (SD 0.68) and the mean AA potassium (K+) was 3.8 mmol/L (SD 0.79). The mean AA potassium value was more than mean ABG potassium and found statistically significant difference (p=0.02). Conclusion: We found that there was no significant difference in the sodium values measured by the ABG analyzer and the autoanalyzer. However, there was a significant difference in the potassium values measured by these instruments.

Authors and Affiliations

Dipti Basavaraj Sanakal, Sagar Chandrakant Mhetre, Ramesh S Patil, Abdul Kayyum Shaikh

Keywords

Related Articles

Evaluation of the relationship between glycemic parameters and serum uric acid level in type 2 diabetes mellitus patients

Introduction: Previous studies have demonstrated that serum uric acid (SUA) is an independent predictor of incident type 2 diabetes mellitus (T2DM) and have shown the positive association of hyperglycemia with increased...

Speculation of diabetic nephropathy by pro-inflammatory cytokines (IL-6, IL-10) & renal biomolecules

Introduction: Type 2 diabetic nephropathy (T2DN) develops inflammation in kidney which leads to failure. Study designed to evaluate risk of diabetic nephropathy (DN) by inflammatory gene expressions (IL6, IL10) and renal...

Correlation of anthropometric parameters with lipid profile in first year medical students

Introduction: Lifestyle related risk factors are prone to increase the burden of cardiovascular diseases. Thus, the study was carried out in the medical students who are more prone to develop lifestyle diseases because o...

Assessment of glycated hemoglobin and uric acid level in polycystic ovarian syndrome in a Tertiary Care Institute of Marathwada region

Introduction: The Polycystic Ovary Syndrome (PCOS) is one of the most common reproductive endocrine disorders, affecting 5–10% of women in the reproductive age. Insulin resistance is the hallmark of this disorder. PCOS h...

A study on estimation of serum ferritin in type 2 diabetes mellitus cases on oral hypoglycemic agents

Introduction: Diabetes mellitus is a metabolic disorder characterized by hyperglycemia and associated micro and macro vascular complications on long duration. Insulin resistance is associated with onset of type 2 DM and...

Download PDF file
  • EP ID EP242967
  • DOI -
  • Views 81
  • Downloads 0

How To Cite

Dipti Basavaraj Sanakal, Sagar Chandrakant Mhetre, Ramesh S Patil, Abdul Kayyum Shaikh (2016). Reliability of blood gas analyzer for the measurement of electrolytes - A comparative study. International Journal of Clinical Biochemistry and Research, 3(4), 376-379. https://europub.co.uk/articles/-A-242967