Reliability of goniometry to determine the hip range of motion

Abstract

Purpose: The purpose of this study was to determine the intra-tester and inter-tester reliability of goniometric measurements when measuring the hip joint. Also this study aimed at determining the validity and reliability of goniometry as a tool to diagnose hip pathologies and record the hip range of motion. Materials and Methods: Fifteen recreationally active male participants (age 26.67 + 4.84 years) and five physiotherapists took part in this study. Measurement values were got by performing passive range of motion on each participant. Angles derived from the goniometry measurements were compared to the known standard angles of the hip range of motion. An intervention was also performed to see the difference in measurement values after sensitising the physiotherapists to methods of performing goniometry accurately and get precise and valid results. Intraclass coefficient correlations (ICC) were performed to see the correlation between inter-tester and intra-tester measurements. The Root mean square error (RMSE) was used to determine the accuracy of goniometric values got by physiotherapists after the intervention. The Root mean square error of goniometric measurements of the hip range of motion was calculated in reference to standard values (RMSE- 8-18). Results: The left sided hip internal rotation showed the highest deviation from the standard (RMSE- 16.20). Both sided hip extensions were the least deviated from standards (left- 8.00; right- 8.49). The intraclass coefficient correlations in intra-tester values were persistently higher than 0.70 whereas in the inter-tester setting, the values were less than 0.70. Conclusion: The intra-tester reliability was higher than the inter-tester reliability in our study. We observed that the goniometric measurement values were most reliable for hip extension and least for internal and external rotation, followed by hip abduction and adduction.

Authors and Affiliations

Dhammapal Sahebrao Bhamare, Pinakin Prakash Ayare, Ashwinkumar Vasant Khandge, Abhijeet Sudhir Shroff, Prafulla Herode

Keywords

Related Articles

An epidemiological study to calculate angle between transepicondylar axis and posterior condylar axis of distal femur on MRI in Indian population

Introduction: Rotational positioning of femoral component is a critical aspect of total knee arthroplasty and evaluation of the landmark for rotation of distal femur is a challenge. Most Orthopaedic Surgeons prefer to us...

A study on uterine and vaginal arteries and their clinical significance

Background: The anterior division of the internal iliac artery usually gives origin to the uterine artery and vaginal artery in common. Uterine artery travels in cardinal ligament to reach uterus by crossing the ureter a...

Surgical management of fractures of distal end radius with locking compression plate

Background: Use of fixed angle locking plates with locking screws for fractures of distal radius support the subchondral bone and resist axial forces and an additional benefit is it provides additional strength to fixati...

Comparative evaluation of hydrogel dressing with conventional dressing in diabetic foot ulcers

Introduction: Diabetic foot is a common problem in this part of the country. In patients with diabetic foot and pressure ulcers, early intervention with biological therapy will either halt progression or result in rapid...

Incarcerated sigmoid colon with gangrenous appendices epiploicae: A rare case report

Incarcerated inguinal hernia is a common diagnosis in patients presenting with a painful and not reducible groin mass. Sliding hernias are supposed to be more anatomically challenging for a surgeon than an uncomplicated...

Download PDF file
  • EP ID EP264950
  • DOI 10.17511/ijoso.2017.i3.03
  • Views 135
  • Downloads 0

How To Cite

Dhammapal Sahebrao Bhamare, Pinakin Prakash Ayare, Ashwinkumar Vasant Khandge, Abhijeet Sudhir Shroff, Prafulla Herode (2017). Reliability of goniometry to determine the hip range of motion. Surgical Update: International Journal of Surgery and Orthopedics, 3(3), 66-71. https://europub.co.uk/articles/-A-264950