Reliable and Energy Efficient MAC Mechanism for Patient Monitoring in Hospitals

Abstract

In medical body area network (MBAN) sensors are attached to a patient’s body for continuous and real-time monitoring of biomedical vital signs. Sensors send patient’s data to hospital base station so that doctors/caregivers can access it and be timely informed if patient’s condition goes critical. These tiny sensors have low data rates, small transmission ranges, limited battery power and processing capabilities. Ensuring reliability in MBAN is important due to the critical nature of patient’s data because any wrong/missing/delayed data can create a situation in which doctors may take wrong decisions about patient’s health which can have fatal results. Data transmission reliability in MBAN can be ensured by retransmissions, acknowledgments or guaranteed time slot mechanism but it causes more power consumption. We propose an efficient MAC mechanism to achieve both reliability and energy efficiency at an acceptable trade-off level. The proposed MAC mechanism not only overcomes the limitations of ZigBee MAC mechanism such as inefficient CSMA/CA and underutilization of guaranteed time slots, but also adapts for different traffic types such as emergency and normal traffic. Our results show that application level throughput and packet delivery ratio increase and packet loss decreases. We also optimize energy utilization by tuning macMaxCSMABackoffs and macMinBE parameters of ZigBee MAC mechanism.

Authors and Affiliations

Madiha Fatima, Adeel Baig, Irfan Uddin

Keywords

Related Articles

Integrating Service Design and Eye Tracking Insight for Designing Smart TV User Interfaces

This research proposes a process that integrate service design method and eye tracking insight for designing a Smart TV user interface. The Service Design method, which is utilized for leading the combination of the qual...

Repetitive Control based on Integral Sliding Mode Control of Matched Uncertain Systems

This paper proposed an integral sliding mode control scheme based on repetitive control for uncertain repetitive processes with the presence of matched uncertainties, external disturbances and norm-bounded nonlinearities...

An approach of inertia compensation based on electromagnetic induction in brake test

This paper briefly introduced the operational principle of the brake test bench, and points out the shortcomings when controlling the current of brake test, which means the reference measuring data is instantaneous. Aime...

mSCTP Based Decentralized Mobility Framework 

To conceive the full potential of wireless IP services, Mobile Nodes (MNs) must be able to roam seamlessly across different networks. Mobile Stream Control Transmission Protocol (mSCTP) is a transport layer solution, whi...

Download PDF file
  • EP ID EP408910
  • DOI 10.14569/IJACSA.2018.091064
  • Views 57
  • Downloads 0

How To Cite

Madiha Fatima, Adeel Baig, Irfan Uddin (2018). Reliable and Energy Efficient MAC Mechanism for Patient Monitoring in Hospitals. International Journal of Advanced Computer Science & Applications, 9(10), 522-537. https://europub.co.uk/articles/-A-408910