Remaining Life Assessment of Kotabaru 2x7 MW Coal Fired Power Plant Circulating Water A252 Gr 2 Intake Pipe by Inspection Method

Journal Title: International Journal of Current Science Research and Review - Year 2024, Vol 7, Issue 05

Abstract

Kotabaru power plant is a power plant that was built in 2010 and currently the construction work is pending. The construction work stopped in 2014 and based on Kotabaru power plant construction final quantity report, Kotabaru construction work progress is 79,61% up to now. Kotabaru power plant uses open cooling system and takes seawater as cooling water resources. The seawater distribute through intake pipeline which use A252 grade 2 material 600 mm and 800 mm diameter pipeline with 3PL coating and rubber lining inside the pipe. The pipeline distribute the water in 3.184.739 kg/hr flow rate and 5 kg/cm2 G pressure. These pipeline material was on site in 2013 and it was not constructed yet. In 2022 Kotabaru power plant is planned to continue the construction work progress. It was about 9 years of pipeline material on Kotabaru power plant site and these pipeline is exposed to the environment such as sunlight, temperature, oxygen, water, and contaminants and cause a primer failure, especially ultraviolet light (UV) from the sunlight is the main damaging factor. Ultraviolet light from sunlight is high enough to break the coating of pipeline. Inspection and assess the pipeline can help the management to figure out pipeline actual condition. More effective inspections can reduce the risk level by reducing the frequency of future failures, through corrective and preventive action. In general, the purpose of this method is classify all risk level equipment, calculate the risk value of all equipment and it can help to make a decision to the next construction period. The service lifetime of pipeline prediction can be determined by actual pipe condition by use corrosion test and actual thickness dimension of the pipeline. This method will inform the life time prediction of the pipeline that should be meet the 15 years life time required and also inform the risk matrix value of all pipeline equipment on the site.

Authors and Affiliations

Hafidz Nufi Hartanto , Agus Suprihanto, Gunawan Dwi Haryadi,

Keywords

Related Articles

Marketing Strategy for a Premium Service Office Provider in a Competitive Market in Jakarta. Case Study: The Executive Centre

The rise of remote work, the gig economy, and the demand for flexible workspaces have significantly impacted the traditional office market, necessitating innovative marketing strategies. This study aims to explore the ma...

The Effects of Central Government Financial Allocation on the Provision of Quality Maternal Health Care in Kampala City

The relationship between devolution and service delivery has been a matter of inquiry for the past three decades. This paper aimed to examine the impact of Central Government financial allocation on the quality of delive...

Proposed Business Strategy for Implementation of Green Port at Merak Ferry Port to Achieve Sustainability

Climate change is a challenge for the global world, requiring immediate action to reduce its impact on the environment. Indonesia is a party to the Paris Agreement, where Indonesia is committed to reducing reduce greenho...

The Role of Artificial Intelligence in Enhancing Employee Performance through SHRM and Organizational Creativity at ABC Bank Yogyakarta Area Office

This study explores the role of Artificial Intelligence (AI) in mediating the effects of Sustainability Human Resource Management (SHRM) and Organizational Creativity on employee performance. Conducted at ABC Bank’s Yogy...

Discerning Digital from Canvas: Investigating Visual Distinction between AI-Generated Art and Actual Art among Far Eastern University's Institute of Architecture and Fine Arts (IARFA) and Non-IARFA Students

Artificial Intelligence is one of the current generation’s inventions that has been widely used. It has helped make lives easier, especially regarding appliances and business, and it has also altered various industries,...

Download PDF file
  • EP ID EP735600
  • DOI 10.47191/ijcsrr/V7-i5-60
  • Views 37
  • Downloads 1

How To Cite

Hafidz Nufi Hartanto, Agus Suprihanto, Gunawan Dwi Haryadi, (2024). Remaining Life Assessment of Kotabaru 2x7 MW Coal Fired Power Plant Circulating Water A252 Gr 2 Intake Pipe by Inspection Method. International Journal of Current Science Research and Review, 7(05), -. https://europub.co.uk/articles/-A-735600