Repeatability of in-vitro optical quality measurements of intraocular lenses with a deflectometry technique effect of the toricity

Journal Title: International Journal of Ophthalmology - Year 2018, Vol 11, Issue 7

Abstract

"AIM: To evaluate the repeatability of an optical device for measuring the Zernike coefficients of toric intraocular lenses (IOLs) and assess whether its toricity has any impact in its repeatability. METHODS: An experienced technician used the NIMO TR1504 to measure the Zernike coefficients 30 times for an aperture of 4.50 mm for all lenses included. The IOLs included were divided into two group: toric and non-toric ones. The cylindrical powers of the toric lenses included in the present study were 1.00, 1.50, 2.25, 3.00 and 3.75 D. Finally, the repeatability of the NIMO TR1504 was described in terms of within subject standard deviation (Sw) and repeatability limit. RESULTS: The Sw was smaller than 0.011 µm for both lens groups and all Zernike coefficients, and the difference between both groups was smaller than 0.004 µm for all Zernike coefficients. Regarding the repeatability limit, this value was smaller than 0.025 µm for the toric lens group, and smaller than 0.031 µm for the non-toric lens one for all Zernike coefficients. Furthermore, the maximum difference between both lens groups was 0.010 µm. CONCLUSION: The repeatability of the NIMO TR1504 to measure the optical quality is high and independent of the lens toricity. These results reflect that this system is robust and could be used to measure the in-vitro optical quality of either toric or non-toric IOLs."

Authors and Affiliations

Alberto Domínguez-Vicent

Keywords

Related Articles

Remodeled structure and reduced contractile responsiveness of ocular ciliary artery in spontaneously hypertensive rats

"AIM: To investigate the alterations in both structure and contractile responsiveness of ocular ciliary artery (OCA) in spontaneously hypertensive rat (SHR). METHODS: In this experiment, 20-week-old male SHR and Wistar K...

Quality of life in glaucoma patients after selective laser trabeculoplasty

"AIM: To compare quality of life and treatment satisfaction between patients who had selective laser trabeculoplasty (SLT) and those on medication. METHODS: A prospective clinical trial on 143 glaucoma patients that rece...

Subfoveal choroidal thickness and volume in severe internal carotid artery stenosis patients

"AIM: To demonstrate the differences of retinal and choroidal structure changes in internal carotid artery (ICA) patients of China by enhanced-depth imaging optical coherence tomography (EDI-OCT). METHODS: A retrospectiv...

Diverse roles of macrophages in intraocular neovascular diseases: a review

Macrophages are involved in angiogenesis, and might also contribute to the pathogenesis of intraocular neovascular diseases. Recent studies indicated that macrophages exert different functions in the process of intraocul...

Responsiveness and minimal clinically important difference of the Chinese version of the Low Vision Quality of Life Questionnaire after cataract surgery

"AIM: To investigate the Chinese version of the Low Vision Quality of Life Questionnaire (CLVQOL) as an instrument for obtaining clinically important changes after cataract surgery. METHODS: Patients underwent cataract s...

Download PDF file
  • EP ID EP482460
  • DOI 10.18240/ijo.2018.07.11
  • Views 54
  • Downloads 0

How To Cite

Alberto Domínguez-Vicent (2018). Repeatability of in-vitro optical quality measurements of intraocular lenses with a deflectometry technique effect of the toricity. International Journal of Ophthalmology, 11(7), -. https://europub.co.uk/articles/-A-482460