RESULTS OF TESTS OF LIGHTNING-RODS WITH UNIVERSAL CLAMPS BY THE APERIODIC IMPULSES OF CURRENT OF ARTIFICIAL LIGHTNING WITH THE PEAK-TEMPORAL PARAMETERS RATIONED ON FOREIGN STANDARDS
Journal Title: Електротехніка і Електромеханіка - Year 2015, Vol 0, Issue 3
Abstract
Purpose. Test in obedience to the requirements of row of operating foreign standards of round metallic lightning-rods with the flat metallic universal clamps of the special type on firmness to direct action of аperiodic impulses of current of temporal form 10/350 μs by amplitude of 50 кА (N− class) and 100 кА (H− class). Methodology. The order of leadthrough of these tests is certain the followings normative documents: International IEC 62305-1: 2010, Russian national GOST R IEC 62305-1-2010 and German national DIN EN 50164-1:2008 Standards. Results. Conducted on a powerful high-voltage pulsed current of artificial linear lightning with the peak-temporal parameters and admittances of test rationed on the indicated foreign standards rationed that all of the lightning-rods tested in collection with universal clamps, isolating holders and ceramic elements of roof of technical building were survive electrodynamics and electrothermal action of in-use single short blow of an artificial storm digit. Originality. First in domestic practice the similar model tests of lightning-rods are conducted with universal clamps, executed from different explorer materials, on firmness to flowing to on by it the indicated large impulsive currents of artificial lightning. Practical value. Real firmness to lightning of round copper and zincked steel lightning-rods is certain with the flat copper, zincked steel and non-rusting steel universal clamps of the special execution.
Authors and Affiliations
M. I. Baranov, G. M. Koliushko, E. V. Kuzminskiy, Yu. I. Mysyuk, S. V. Rudakov
INFLUENCE OF CORONARY DISCHARGE PARAMETERS ON THE EFFICIENCY OF LIGHTNING PROTECTION SYSTEM ELEMENTS
Purpose. Investigation of the formation of space charge in the region of the apex of lighting rod, under the action of the electric field of a thunderstorm cloud, to evaluate the efficiency of elements of lighting protec...
CALCULATION OF MAGNETIC FIELD OF THREE-PHASE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS COVERED BY FERROMAGNETIC CORES
In this paper we obtain compact expressions for the magnetic field shielding factor of a high-voltage three-phase cable line consisting of single-core cables with two-point bonded cable shields and ferromagnetic cores in...
THE METROLOGY SUPPORT IN UKRAINE OF TESTS OF OBJECTS OF ENERGY, AVIATION AND SPACE-ROCKET ENGINEERING ON RESISTIBILITY TO ACTION OF PULSES OF CURRENT (VOLTAGE) OF ARTIFICIAL LIGHTNING AND COMMUTATION PULSES OF VOLTAGE
Purpose. Presentation and analysis of the modern state of the metrology support in Ukraine of model tests of equipment of objects of energy on resistibility to the action of pulsed current (voltage) of artificial lightni...
SOME FEATURES OF DYNAMIC CHARACTERISTICS OF BUMPERS WITH PERMANENT MAGNETS
This article describes the features of the dynamics of the bumper with permanent magnets. Pictures of the magnetic field in 3D are presented, transients are calculated. It is shown that operation of this system depends o...
ANALYSIS OF OPTIMUM OPERATING MODES OF POWER TRANSFORMERS UNDER OPERATING CONDITIONS
Purpose. The study of parallel operation optimal modes of transformer equipment for a variety of operating conditions: same or different types of transformers, with or without reactive power flows. Methodology. Losses of...