Retention and Deformation of Cobalt-Chromium and High-Impact Polyamide Clasps

Journal Title: Meandros Medical and Dental Journal - Year 2018, Vol 19, Issue 1

Abstract

Objective: The use of metal clasps especially in anterior region may cause aesthetic problems. Polyamide resin has been suggested as an alternative aesthetic denture clasp material. This study compared the retentive force and deformation of cobalt-chromium and polyamide clasps after 36 months of simulated clinical use. Materials and Methods: The retentive force for clasp removal was measured in distilled water using a custom-made apparatus with intervals corresponding to 0, 6, 12, 18, 24, 30 and 36 months of simulated clinical use. The distance (mm) between the retentive and reciprocal clasp tips was measured using a microscope before and after the insertion-removal procedures. Results: Significant difference was observed in distance between clasp tips for metal clasps between baseline and 36 months for molars and premolars (p<0.05). Likewise, retentive force showed significant difference (p<0.05) for cobalt-chromium between baseline and 36 months, while polyamide clasps did not show significant difference (p>0.05). Conclusion: Polyamide clasps could be alternative to metal clasps particularly on premolars with reliable retention and deformation.

Authors and Affiliations

Övül Kümbüloğlu, Yasemin Kulak Özkan, Tuğberk Arda, Mutlu Özcan

Keywords

Related Articles

Effects of Intra-Articular Platelet-Rich Plasma Administration in Temporomandibular Joint Arthritis: An Experimental Study

Objective: Osteoarthritis is defined as a disease that begins with focal and progressive destruction in articular cartilage with biomechanical, biochemical, inflammatory and immunologic reactions and may cause pathologic...

Effect of Initial Periodontal Treatment on Cardiovascular Risk Markers in Patients with Severe Chronic Periodontitis

Objective: The aim of the study was to determine the influence of initial periodontal treatment in patients with severe chronic periodontitis on inflammatory markers related to risk for cardiovascular diseases. Materials...

A Marker for Evaluation of Oxidative Stress in Patients with Alopecia Areta: Thiol-Disulphide Homeostasis

Objective: Alopecia areata (AA) is a disorder characterized by non-scarring hair loss, whose etiology involves oxidative stress. We aimed to determine the role of thiol/disulphide levels in AA pathogenesis and to investi...

Can Allergen Specific Immunotherapy Induce Familial Mediterranean Fever Attacks?

Allergen-specific immunotherapy is a treatment aimed to reduce allergic symptoms and need for medication use after exposure to specific allergens. Allergen-specific immunotherapy is the only curative treatment that can c...

The Hemostatic Effect of Ankaferd Blood Stopper in Rat Bleeding Models with Antithrombotic Drug Therapy: An Experimental In Vivo Study

Objective: Ankaferd blood stopper is a mixture of five medicinal plant extracts used as a hemostatic agent for management of external hemorrhage. The aim of this study was to evaluate the hemostatic effects of Ankaferd b...

Download PDF file
  • EP ID EP283429
  • DOI 10.4274/meandros.33043
  • Views 96
  • Downloads 0

How To Cite

Övül Kümbüloğlu, Yasemin Kulak Özkan, Tuğberk Arda, Mutlu Özcan (2018). Retention and Deformation of Cobalt-Chromium and High-Impact Polyamide Clasps. Meandros Medical and Dental Journal, 19(1), 25-31. https://europub.co.uk/articles/-A-283429