Role of 320 Detector Row CT Perfusion in Assessment of Myocardial Perfusion

Journal Title: The Egyptian Journal of Hospital Medicine - Year 2018, Vol 71, Issue 5

Abstract

<span>Aim of the work: </span><span>this study aimed to evaluate the coronary artery morphology and myocardial perfusion by single reproducible non-invasive contrast enhanced CT acquisition by using DECT scanners with high sensitivity and specificity as well as high diagnostic accuracy without the need to increase the contrast material or radiation dose. </span><span>Patients and Methods</span><span>: this study was done during the period from October 2016 to December ,2017; age was ranged between 42 to 73 years old, were 35 patients with CAD diagnosed by cCTA underwent DECT for assessment of myocardial perfusion. The study included 35 patients referred for DECT myocardial perfusion examination in the Police Authority Hospitals, Radiodiagnosis Department in Cairo after diagnosing by cCTA. Each patient included in the study was subjected to full history taking, reviewing medical sheet, cCTA and CT myocardial perfusion examination. Technique was performed by using Aquilion one dynamic volume 320 detector rows CT, Toshiba Medical System, Tochigi-ken, Japan. </span><span>Results</span><span>: our study showed a significant correlation and good agreement between the findings of DECT myocardial perfusion defects and the findings of stenosis and its degree on cCTA on a segmental basis with 83% sensitivity, 87% specificity, 86% accuracy, 74% positive predictive value and 92% negative predictive value. </span><span>Conclusion</span><span>: DECT myocardial perfusion has high diagnostic as compared to cCTA as the gold reference standard</span><span>.<br /> </span>

Authors and Affiliations

Eman Helal

Keywords

Related Articles

Glucose-6-phosphate dehydrogenase deficiency (G6PD) (Favism) in Dammam, Eastern Province of Saudi Arabia

<strong>Background</strong>: Glucose-6-phosphate dehydrogenase deficiency is an X linked recessive disorder expressed mostly in males. It is the most common enzyme deficiency worldwide, causes a spectrum of disease inclu...

The Effectiveness and Tolerability of Budesonide in Treatment of Autoimmune Hepatitis: A Systematic Review

<strong>Background:</strong> Budesonide was effective in treating and keeping short-term remission with a fewer steroid-specific side effects in contrast to prednisone. Contradicting outcomes were detailed on the efficie...

The Prevalence of Iron Deficiency Anemia and its Associated Risk Factors among a Sample of Females in Riyadh, Saudi Arabia

<span>Objectives: </span><span>To assess the prevalence of iron deficient anemia (IDA) within Saudi Arabian females and to examine the risk factors leading to the IDA.<br /> </span><span>Methods: </span><span>A cross-sec...

Pattern of Gastrointestinal Diseases among Elderly Patients in Arar City,Kingdom of Saudi Arabia (KSA)

<span>T</span><span>he world's population is aging and the number of people who are ≥ 60 years old increased worldwide. </span><span>The elderly population is susceptible to various benign and malignant diseases. Gastroi...

Wound Management in Primary Care: A Review

In this review, we discuss assessments methods of patient’s step by step in primary care. We outline the cleansing methods of wounds and guidelines for wound management depending on the type of wound. We review the most...

Download PDF file
  • EP ID EP583950
  • DOI -
  • Views 86
  • Downloads 0

How To Cite

Eman Helal (2018). Role of 320 Detector Row CT Perfusion in Assessment of Myocardial Perfusion. The Egyptian Journal of Hospital Medicine, 71(5), 3221-3228. https://europub.co.uk/articles/-A-583950