ROLE OF BREAST ULTRASOUND IN EVALUATION OF BIRADS 3 AND BIRADS 4 BREAST MASSES

Journal Title: Journal of Evolution of Medical and Dental Sciences - Year 2017, Vol 6, Issue 45

Abstract

BACKGROUND Breast Ultrasound (US) is widely used as a diagnostic tool in evaluating mammographically detected masses, (1) palpable lumps, (2,3) nipple discharge(4) and in guiding percutaneous biopsy.(5) Breast ultrasound is a primary diagnostic tool along with mammography for the evaluation of breast masses. Aim- To determine the accuracy of Breast Ultrasound in evaluating BI-RADS 3 and 4 breast masses with pathologic diagnosis as reference gold standard. MATERIALS AND METHODS Study was conducted in the period, December 2015 to December 2016. A total of 756 patients who presented to the Surgery outpatient department with complaints of breast lump, pain or nipple discharge were subjected to breast imaging. From 756 patients, 143 patients who had BIRADS 3 and 4 mass were selected for the study. Patients with masses that fulfilled the BI-RADS 3 and 4 were enrolled in the study. Breast ultrasound with and without Doppler performed in these patients with GE Voluson S6 (Linear Array 4 - 12 MHz, Curved Array 2 - 8 MHz). Informed written consent for the ultrasound-guided biopsy procedures was obtained from each patient. RESULTS All the 143 breast masses were evaluated and categorised according to the BI-RADS classification on B mode US. A total of 51 masses were categorised into BI-RADS 3 and 92 masses into BI-RADS 4. Among the 51 BI-RADS category 3 masses, only 4 (7.8%) were malignant. Of the 92 masses of category 4, 75 (81.5%) were malignant on histopathology. Thus, the B mode US had a sensitivity of 94.9% and specificity of 73.4%, positive predictive value of 81.5% and negative predictive value of 92.2%; (P value < 0.001) in detecting malignancy. CONCLUSION Breast ultrasonography is an appropriate tool in the detection of cancer and should be included in the workup of symptomatic breast disease. Breast ultrasound has a very high sensitivity in detecting malignancies and guiding further management of the suspicious lesions. But the occurrence of false positive diagnosis in the clinical settings like that of inflammatory breast disease should also be considered and the management be decided after correlation with the clinical data and the biopsy results.

Authors and Affiliations

Adarsh A. D, Krishna Kumar R, Venugopal Kodumu, Manas Kumar Bora

Keywords

Related Articles

POST-OPERATIVE WOUND INFECTIONS IN ELECTIVE SURGERIES- A STUDY AT GOVERNMENT GENERAL HOSPITAL, GUNTUR

BACKGROUND Surgical Site Infections (SSI) place a significant burden on both the patient and health system, prolongs hospital stay and adds to hospital costs. MATERIALS AND METHODS Patients were selected from general sur...

COMPARISON OF VISUAL OUTCOMES OF DEEP ANTERIOR LAMELLAR KERATOPLASTY AND PENETRATING KERATOPLASTY

BACKGROUND Deep Anterior Lamellar Keratoplasty (DALK) has been used as an alternative to PK in the last few years in cases with intact endothelium, such as stromal scar, stromal dystrophies, and keratoconus. This surgica...

THERAPEUTIC EFFECTS OF CARBOGEN THERAPY IN SUDDEN SENSORINEURAL HEARING LOSS

BACKGROUND Sudden Hearing Loss (SHL) is a rare disease accounting for 1% of all sensorineural hearing loss cases, but it is considered an otological emergency. The sooner the treatment begins, the outcome proves to be be...

A DESCRIPTIVE STUDY OF INGUINAL HERNIOPLASTY IN A TERTIARY CARE CENTRE

BACKGROUND Hernia may be defined as a protrusion of abdominal viscera outside the abdominal cavity through a natural or acquired defect. Inguinal hernias present with a lump in the groin that goes away with minimal press...

APPLICATION OF LEAN SIX-SIGMA APPROACH TO REDUCE BIOMEDICAL EQUIPMENTS BREAKDOWN TIME AND ASSOCIATED DEFECTS

BACKGROUND Lean Six Sigma is an advanced methodology of quality management and quality improvement. Lean Six Sigma implementation in equipment maintenance can be a good solution, which can reduce the waste and variation...

Download PDF file
  • EP ID EP216829
  • DOI 10.14260/Jemds/2017/760
  • Views 52
  • Downloads 0

How To Cite

Adarsh A. D, Krishna Kumar R, Venugopal Kodumu, Manas Kumar Bora (2017). ROLE OF BREAST ULTRASOUND IN EVALUATION OF BIRADS 3 AND BIRADS 4 BREAST MASSES. Journal of Evolution of Medical and Dental Sciences, 6(45), 3524-3527. https://europub.co.uk/articles/-A-216829