ROLE OF BREAST ULTRASOUND IN EVALUATION OF BIRADS 3 AND BIRADS 4 BREAST MASSES

Journal Title: Journal of Evolution of Medical and Dental Sciences - Year 2017, Vol 6, Issue 45

Abstract

BACKGROUND Breast Ultrasound (US) is widely used as a diagnostic tool in evaluating mammographically detected masses, (1) palpable lumps, (2,3) nipple discharge(4) and in guiding percutaneous biopsy.(5) Breast ultrasound is a primary diagnostic tool along with mammography for the evaluation of breast masses. Aim- To determine the accuracy of Breast Ultrasound in evaluating BI-RADS 3 and 4 breast masses with pathologic diagnosis as reference gold standard. MATERIALS AND METHODS Study was conducted in the period, December 2015 to December 2016. A total of 756 patients who presented to the Surgery outpatient department with complaints of breast lump, pain or nipple discharge were subjected to breast imaging. From 756 patients, 143 patients who had BIRADS 3 and 4 mass were selected for the study. Patients with masses that fulfilled the BI-RADS 3 and 4 were enrolled in the study. Breast ultrasound with and without Doppler performed in these patients with GE Voluson S6 (Linear Array 4 - 12 MHz, Curved Array 2 - 8 MHz). Informed written consent for the ultrasound-guided biopsy procedures was obtained from each patient. RESULTS All the 143 breast masses were evaluated and categorised according to the BI-RADS classification on B mode US. A total of 51 masses were categorised into BI-RADS 3 and 92 masses into BI-RADS 4. Among the 51 BI-RADS category 3 masses, only 4 (7.8%) were malignant. Of the 92 masses of category 4, 75 (81.5%) were malignant on histopathology. Thus, the B mode US had a sensitivity of 94.9% and specificity of 73.4%, positive predictive value of 81.5% and negative predictive value of 92.2%; (P value < 0.001) in detecting malignancy. CONCLUSION Breast ultrasonography is an appropriate tool in the detection of cancer and should be included in the workup of symptomatic breast disease. Breast ultrasound has a very high sensitivity in detecting malignancies and guiding further management of the suspicious lesions. But the occurrence of false positive diagnosis in the clinical settings like that of inflammatory breast disease should also be considered and the management be decided after correlation with the clinical data and the biopsy results.

Authors and Affiliations

Adarsh A. D, Krishna Kumar R, Venugopal Kodumu, Manas Kumar Bora

Keywords

Related Articles

EVALUATION OF PSYCHIATRIC DISABILITY AMONG PATIENTS WITH SCHIZOPHRENIA IN RELATION TO DURATION OF UNTREATED ILLNESS- A CROSS-SECTIONAL STUDY

BACKGROUND Schizophrenia is a chronic mental illness associated with major disability in several spheres of a person’s functioning. Duration of untreated illness is one of the important reasons for severe disability. Aim...

ROLE OF DIRECT IMMUNOFLUORESCENCE ON TZANCK SMEAR IN PEMPHIGUS VULGARIS

BACKGROUND The Tzanck smear is a simple, sensitive, and rapid test to diagnose pemphigus vulgaris (PV), a life-threatening autoimmune blistering disorder. The presence of acantholytic cells in cytology is indicative of,...

COMPARATIVE STUDY OF CRP AND SERUM ALBUMIN AS STRESS RESPONSE MARKERS IN LAPAROSCOPIC VERSUS OPEN CHOLECYSTECTOMY

BACKGROUND Body responds to any trauma and surgery with ‘stress response’ in the form of metabolic and hormonal changes. Change in ‘Acute Phase Proteins’ (APP) like C-Reactive Proteins and Albumin occurs after surgery. L...

SHORT-TERM OUTCOME OF INTRAVENOUS IRON THERAPY FOR IRON DEFICIENCY ANAEMIA AT JNIMS, IMPHAL- A PRELIMINARY REPORT

BACKGROUND Iron deficiency anaemia (IDA) comprises of 50% of anaemia cases worldwide. The treatment consists of oral iron therapy and IV iron therapy. However, both of them may have their own side effects. Oral iron may...

ROLE OF FUNDUS FLUORESCEIN ANGIOGRAPHY IN EVALUATION OF RETINAL DISORDERS

BACKGROUND Retinal disorders are the leading cause of legal blindness in the age group of 20 to 65 years. Approximately 18 million people in India have severely impaired vision due to retinal diseases. It has been nearly...

Download PDF file
  • EP ID EP216829
  • DOI 10.14260/Jemds/2017/760
  • Views 98
  • Downloads 0

How To Cite

Adarsh A. D, Krishna Kumar R, Venugopal Kodumu, Manas Kumar Bora (2017). ROLE OF BREAST ULTRASOUND IN EVALUATION OF BIRADS 3 AND BIRADS 4 BREAST MASSES. Journal of Evolution of Medical and Dental Sciences, 6(45), 3524-3527. https://europub.co.uk/articles/-A-216829