ROLE OF BREAST ULTRASOUND IN EVALUATION OF BIRADS 3 AND BIRADS 4 BREAST MASSES

Journal Title: Journal of Evolution of Medical and Dental Sciences - Year 2017, Vol 6, Issue 45

Abstract

BACKGROUND Breast Ultrasound (US) is widely used as a diagnostic tool in evaluating mammographically detected masses, (1) palpable lumps, (2,3) nipple discharge(4) and in guiding percutaneous biopsy.(5) Breast ultrasound is a primary diagnostic tool along with mammography for the evaluation of breast masses. Aim- To determine the accuracy of Breast Ultrasound in evaluating BI-RADS 3 and 4 breast masses with pathologic diagnosis as reference gold standard. MATERIALS AND METHODS Study was conducted in the period, December 2015 to December 2016. A total of 756 patients who presented to the Surgery outpatient department with complaints of breast lump, pain or nipple discharge were subjected to breast imaging. From 756 patients, 143 patients who had BIRADS 3 and 4 mass were selected for the study. Patients with masses that fulfilled the BI-RADS 3 and 4 were enrolled in the study. Breast ultrasound with and without Doppler performed in these patients with GE Voluson S6 (Linear Array 4 - 12 MHz, Curved Array 2 - 8 MHz). Informed written consent for the ultrasound-guided biopsy procedures was obtained from each patient. RESULTS All the 143 breast masses were evaluated and categorised according to the BI-RADS classification on B mode US. A total of 51 masses were categorised into BI-RADS 3 and 92 masses into BI-RADS 4. Among the 51 BI-RADS category 3 masses, only 4 (7.8%) were malignant. Of the 92 masses of category 4, 75 (81.5%) were malignant on histopathology. Thus, the B mode US had a sensitivity of 94.9% and specificity of 73.4%, positive predictive value of 81.5% and negative predictive value of 92.2%; (P value < 0.001) in detecting malignancy. CONCLUSION Breast ultrasonography is an appropriate tool in the detection of cancer and should be included in the workup of symptomatic breast disease. Breast ultrasound has a very high sensitivity in detecting malignancies and guiding further management of the suspicious lesions. But the occurrence of false positive diagnosis in the clinical settings like that of inflammatory breast disease should also be considered and the management be decided after correlation with the clinical data and the biopsy results.

Authors and Affiliations

Adarsh A. D, Krishna Kumar R, Venugopal Kodumu, Manas Kumar Bora

Keywords

Related Articles

PREVALENCE OF GALLSTONES AMONG PREGNANT WOMEN IN A SOUTH INDIAN DISTRICT

BACKGROUND Gallstone disease is more common in women than men. Pregnancy is a known risk factor for developing gallstones.1 We wanted to assess the prevalence of biliary sludge and gallstone disease during pregnancy. MET...

COMPARATIVE STUDY FOR DETECTION OF H. PYLORI INFECTION BY RAPID UREASE TEST AND HISTOPATHOLOGICAL EXAMINATION IN AL-AMEEN MEDICAL COLLEGE

BACKGROUND H. pylori infection is seen in more than 50 percent of world population and is more common in developing countries than in western countries. We wanted to study the incidence of H. pylori infection in Al-Ameen...

ROLE OF FOCUSED ABDOMINAL SONOGRAPHY FOR TRAUMA IN SOLID ORGAN INJURY IN PAEDIATRIC BLUNT ABDOMINAL TRAUMA

BACKGROUND The term Focused Assessment with Sonography for Trauma (FAST) was coined by Rozycki et al in 1996. It is now termed “focused abdominal sonography for trauma”. It is an emergency ultrasound scan done in abdomin...

&nbsp;“HYGIENE PRACTICES AMONG RURAL SCHOOL CHILDREN IN PUDUCHERRY”

[b]&nbsp;AIM[/b]: To assess the hygiene practices among rural school children. [b]SETTINGS AND[/b] [b]DESIGN[/b]: This cross-sectional study was conducted at Government higher secondary school in rural area of Puduch...

&nbsp;CLINICAL CO RELATION BETWEEN ARTERIAL VERSUS VENOUS AMMONIA LEVELS IN HEPATIC ENCEPHLOPATHY IN CIRRHOSIS OF LIVER

[b]INTRODUCTION:[/b] Hepatic encephalopathy is a reversible neuropsychiatry state that complicates liver disease. Pathogenesis of Hepatic Encephalopathy in chronic liver is function is widely accepted to be due to fa...

Download PDF file
  • EP ID EP216829
  • DOI 10.14260/Jemds/2017/760
  • Views 66
  • Downloads 0

How To Cite

Adarsh A. D, Krishna Kumar R, Venugopal Kodumu, Manas Kumar Bora (2017). ROLE OF BREAST ULTRASOUND IN EVALUATION OF BIRADS 3 AND BIRADS 4 BREAST MASSES. Journal of Evolution of Medical and Dental Sciences, 6(45), 3524-3527. https://europub.co.uk/articles/-A-216829