ROLE OF ECHOGENIC AMNIOTIC FLUID PARTICLES AND OPTICAL DENSITY IN PREDICTION OF RESPIRATORY DISTRESS SYNDROME AND LABOR

Journal Title: Internet Journal of Medical Update - Year 2010, Vol 5, Issue 1

Abstract

This study was aimed to correlate echogenic amniotic fluid particle size (AFPS) in late third trimester to fetal lung maturity and amniotic fluid optical density (AFOD) at labor. AFPS were measured with specified criteria by real time transabdominal USG (3.5MHz) while Amniotic Fluid Index (AFI) was measured during routine antenatal visits. The criteria for AFPS score which are taken into account are the amniotic fluid particle size, number and distribution. Serial AFPS measurements were done till onset of labor. AFPS was correlated to AFOD value at spontaneous labor in 123 women. Uncentrifuged fresh amniotic fluid samples were obtained during ARM/amniotomy and used for AFOD estimation at 650 nm. The mean AFPS and AFOD at onset of labor was found to be 5.14 ± 0.69 mm (3.67 – 6.7 CI 95%) and 1.03 ± 0.31 (0.35 -1.69 CI 95%) respectively in 116 women who delivered normal babies devoid of respiratory distress syndrome (RDS). Serial AFPS measurements showed a definite AFOD surge after a value in the region of 3.8 mm which is obtained culminating in onset of Labor. 28 women (24.1%) had dense clusters of free floating particles across the vertical pool in amniotic fluid with mean AFPS and AFOD of 5.6 ± 0.68 mm and 1.12 ± 0.21 respectively. In 123 women, AFPS < 3.8 mm had sensitivity of 85.74% and positive predictive value of 66.67% in predicting RDS. AFPS serves as a sonological marker for fetal lung maturity and labor. The range of AFOD values can be measured in terms of AFPS (r =0.6, F = 69.8, β= + 0.23, p < 0.001). Serial AFPS estimation predicts fetal maturity and onset of labor.

Authors and Affiliations

Shankar Ram, Sandhya Ram

Keywords

Related Articles

CATASTROPHIC ANTIPHOSPHOLIPID SYNDROME IN LEPROSY

Catastrophic antiphospholipid syndrome is an acute and life threatening variant of antiphospholipid syndrome with a high mortality rate. Many infections are known to be accompanied by the thrombotic manifestations of thi...

RADIATION EXPOSURE FROM DIAGNOSTIC RADIOGRAPHY: AN ASSESSMENT OF X-RAY BEAM COLLIMATION PRACTICE IN SOME NIGERIAN HOSPITALS

This study was carried out to evaluate the X-ray beam collimation practice, among radiographers, as a measure of radiation protection for patients undergoing radiodiagnostic investigations. Inadequate X-ray beam collimat...

Prevalence of Gram-negative Pathogens and their antimicrobial susceptibility in bacterial meningitis in pediatric cases

The present study was conducted to find out the prevalence and spectrum of Gram negative pathogens causing bacterial meningitis and their antimicrobial susceptibility pattern in a tertiary care hospital. The cerebrospina...

Download PDF file
  • EP ID EP144682
  • DOI -
  • Views 83
  • Downloads 0

How To Cite

Shankar Ram, Sandhya Ram (2010). ROLE OF ECHOGENIC AMNIOTIC FLUID PARTICLES AND OPTICAL DENSITY IN PREDICTION OF RESPIRATORY DISTRESS SYNDROME AND LABOR. Internet Journal of Medical Update, 5(1), 3-11. https://europub.co.uk/articles/-A-144682