Role of Image Guided Radiotherapy (IGRT) in Patients Treated with Intensity Modulated Radiotherapy (IMRT) & Volumetric Modulated Arc Therapy (VMAT) in Head and Neck and Pelvic Cancers
Journal Title: Indian Journal of Cancer Education and Research - Year 2018, Vol 6, Issue 1
Abstract
Background: IGRT is the latest development for increasing the precision and accuracy in radiation therapy. Usage of specialized multi professional teams for coordinating geometric verification and use of clearly defined protocols are essential for IGRT. Reducing dose to the OARs using IMRT & VMAT and reducing the size of PTV using IGRT enables radiation dose escalation, which in turn improve the treatment outcomes. Aims: To evaluate set up errors in patients treated with Intensity modulated radiotherapy / Volumetric modulated arc therapy using Cone beam CT (CBCT) in head and neck and pelvic cancer sites and to study adequacy of PTV margin by applying set up errors. Methods and Materials: A total of thirty two patients were enrolled into the study, which included 16 Head and neck site, 16 pelvic sites that were planned with either IMRT or VMAT. CBCT was acquired for each patient on day 1, 2, 3 and thereafter every week until the completion of treatment. The CBCT images were fused with planning CT images. The PTV margin was estimated by calculating the systematic and random errors in X, Y, Z directions. Results: Data collected was analyzed with single sample t test. A total of 288 CBCT were taken for this study. The systematic and random errors were calculated in both head and neck and pelvis 16 patients each. The systematic error for H&N site in cranio caudal (CC), medio lateral(ML), anteroposterior (AP) were 0.2cm, 0.2 cm, 0.2 cm respectively. The random errors in H&N sites patients in CC, ML, and AP were 0.2 cm, 0.2cm, 0.2 cm respectively. The PTV margin for H&N site in CC, ML, AP were 0.7cm, 0.5cm, 0.5cm respectively. For pelvic site, the systematic error in CC, ML, AP were 0.3 cm, 0.2 cm, 0.2cm respectively, where as the random errors were 0.2 cm, 0.3cm, 0.2 cm respectively in the same direction. The estimated PTV margin for pelvic site in CC, ML, AP were 0.8cm, 1.0cm, 0.7cm respectively. Conclusion: For H & N and pelvic sites, treated with IMRT/VMAT the PTV margin of 5mm is not sufficient. Hence treatment verification with IGRT is very crucial to identify and correct the set up errors in order to deliver the planned treatment.
Authors and Affiliations
U. Umamaheswara Reddy
Role of Granulocyte Colony Stimulating Factor Administered During Weekends in Reducing Oral Mucositis of Chemoradiation in Head and Neck Cancers
Introduction: Cancer is a leading cause of morbidity and mortality worldwide. The head and neck cancers form the seventh most common cancer and a major health problem worldwide. Aims: To compare and contrast the role of...
A Case Study on Lung Cancer: Proceedings of 3rd International Meeting of Clinical Practice Guidelines in Oncology
Third International Meeting of Clinical Practice Guidelines in Oncology–2014 and Indian Perspectives was conducted on December 20th 2014. The conference was organized by the unit of medical oncology, Sri Ramachandra Univ...
Chromosomal Abnormalities in Multiple Myeloma: An Observational Study from South India
Recurrent cytogenetic abnormalities are noted throughout the course of multiple myeloma (MM) from the premalignant stage of monoclonal gammopathy of undetermined significance to end-stage disease. The prospective, observ...
The Clinico-Pathological Features in HPV Positive Head and Neck Cancer
Introduction: HPV16 is the most common viral subtype associated with malignant transformation, ranging between 90% and 95% of all cases [8]. It is present in 86.7% of all HPVpositive oropharyngeal SCCs compared with 68.2...
Testicular Tumors in Undescended Testes
Introduction: The failure of testicular descent or cryptorchidism is the most common defect in newborn boys. Cryptorchidism is an established risk factor for infertility and testicular germ cell tumors (TGCT). About 10%...