ROLE OF VCI –OMNIVEIW (4D ULTRASOUND TECHNOLOGY) IN ACCURATE AND FAST DETECTION OF IUCD COMPLICATIONS

Journal Title: European Journal of Pharmaceutical and Medical Research - Year 2017, Vol 4, Issue 6

Abstract

Background and purposes: During 2D ultrasound exam of the pelvis we can suspect or partially detect abnormal position of the IUCD but we need a fast ,easy and an accurate technique to accurately diagnose such IUCD complications to deal with it, particularly if the exam was done without specific complain (the most of our patients are referred from the ER department, the most of the referred ER pateints have no symptoms related to IUCD) ,the 3D sonography has two disadvantages , the first one is that the exam is time consuming (time to acquiring a volume of uterus and relatively long time for reconstructing the images through the multiplanar technique, allows visualization of the appropriate sagittal and coronal views),the second disadvantage is that the exam need the operator to be skilled in 3D orientation and subsequent retrieval of the diagnostic planes from acquired volumes. The aim of this work was to demonstrate the significant role of the VCI - omniview 4D application in an accurate and fast detection of IUCD complications and to decrease the requirement of skills from the operator as in the 3D sonography where the operator needs to choose the diagnostic planes from the acquired volume (i.e. omniview VCI technique is a fast and simple technique as compared to the 3D sonography with the same accuracy) Methods: This observational comparative study was done at Al Salam International Hospital and Al Azhar University Hospitals between June 2013 to December 2016. 74 patients are diagnosed or suspected to have IUCD abnormalities by 2D ultrasound irrespective to their complain, they underwent complementary transabdominal or transvaginal 3D and 4D (3D volume acquisition of the uterus and Omniveiw VCI 3 and 4D technique). Results: In our study, 4 patients are diagnosed by 2D sonography with no more findings was detected by 3D and 4D sonography however the 3D or 4D omniview VCI sonography is important to confirm the diagnosis and to exclude the presence of other findings, the remaining 70 patients are partially diagnosed or not diagnosed by 2D sonography and accurately diagnosed by other modalities , the same accuracy was obtained by the 3D sonography and the 4D omniveiw VCI sonography however the diagnosis by 3D sonography needs more time , more effort and more operator skills. Conclusion and Recommendations: The VCI - omniview 4D sonography is practically better than the 3D sonography in detection of IUCD complications inspite of the same accuracy of both techniques due to the VCI - omniview 4D sonography takes less time and less efforts for detection of the findings and also need less operator skills as compared to the 3D sonography.

Authors and Affiliations

Hussein Montaser

Keywords

Related Articles

GREEN CHEMISTRY IN DRUG DESIGN- A REVIEW

Green chemistry or environmentally benign chemistry is the design of chemical products and processes that reduce or eliminate the use and generation of hazardous substances. Green chemistry emerged from a variety of exis...

ULTRAVIOLET SPECTROPHOTOMETRIC EVALUATION OF DIFFERENT BRANDS OF AZITHROMYCIN DIHYDRATE TABLETS AND CAPSULES SOLD IN NIGERIA.

The aim of this study was to carry out a spectrophotometric and other pharmaceutical quality evaluation of different brands of azithromycin dihydrate tablets and capsules from Nigerian markets and to predict their bioequ...

DOXORUBICIN INDUCED NEURO- AND CARDIOTOXICITIES IN EXPERIMENTAL RATS: PROTECTION AGAINST OXIDATIVE DAMAGE BY THEOBROMA CACAO STEM BARK

80 rats, randomly selected, were divided into 3 treatment groups: pre-, co- and post-treatment; consisting of 6 sub-groups each (5 rats per sub-group): baseline, normal saline (2 mL), α-lipoic acid (20 mg/kg body weight)...

DELETION POLYMORPHISM OF GLUTATHIONE S TRANSFERASES GENES (GSTMI AND GSTTI) IN ARAB POPULATION RESIDING IN UNITED ARAB EMIRATES

The glutathione S-transferase (GST) family of enzymes plays a vital role in phase II biotransformation of environmental carcinogens, pollutants, drugs and other xenobiotics. GSTs are polymorphic, with the form and incide...

TWIN BIRTHS IN SOKOTO: A 5-YEAR REVIEW

Background: Twin pregnancy is of major obstetric importance in Nigeria, not just because the highest incidence in the world occurs here but it also poses higher feto-maternal risks in our low-resource setting due to scar...

Download PDF file
  • EP ID EP629792
  • DOI -
  • Views 148
  • Downloads 0

How To Cite

Hussein Montaser (2017). ROLE OF VCI –OMNIVEIW (4D ULTRASOUND TECHNOLOGY) IN ACCURATE AND FAST DETECTION OF IUCD COMPLICATIONS. European Journal of Pharmaceutical and Medical Research, 4(6), 17-25. https://europub.co.uk/articles/-A-629792