Saturated Virial Coefficient of the Environmentally Friendly Refrigerant Fluids: R365mfc and R152a

Abstract

This work presents the saturated second Virial coefficient of new environmentally friendly refrigerants 1,1- difluoroethane (R152a) , 1,1,1,3,3-Pentafluorbutane (R365mfc) and their mixture. The vapor phase behavior of the mixture was investigated using the Virial equation of state combined with group contribution method of modified UNIFAC. The work has enabled a highly accurate predicted saturated second Virial coefficient data as function of composition in a temperature range of T=260K to T=380K. The Tsonopoulos second Virial coefficient model has been investigated and compared with experimental data of McLinden et.al from National Institute of Standard and Technology (NIST) . The results yielded a maximum deviation of 4.06%, in a temperature range of T=298-300K,whereas, for a temperature range of T=323-325K a maximum deviation less than 2.59% was recognized for R365mfc. A negative deviation less than 12.3% was achieved for R152a.

Authors and Affiliations

Dr. -Ing. Momin E. Abdalla,

Keywords

Related Articles

Optimal Replenishment Policies and Profits for Two-Echelon Inventory Problems with Stochastic Demand

In this paper, a new mathematical model is developed to optimize replenishment policies and profits of a two-echelon distribution inventory system under demand uncertainty. The system consists of a factory warehouse at...

Physico-Chemical Characteristics of Groundwater of Gohparu Tahsil, Shahdol District M.P.) India

Water is an elixir of life and it is a basic need for all humans. The major sources of water are surface water and groundwater. Groundwater is the basic requirement of rural and urban areas and it is essential for a hea...

Hydro processing Of Bio Oils, Effect Of Parameters – A Review

Rising energy demands and growing environmental concerns coupled with decline in petroleum reserves has stimulated the growth of bio fuels, an alternative to conventional fuel. This uses renewable oil derived from bioma...

Exhaust Gas Recirculation in CI Engines

Exhaust Gas Recirculation (EGR) is being widely used to reduce and control the oxides of nitrogen (NOx) emission from diesel engines. When combustion chamber temperature reaches 2500ºF or 1370ºC, nitrogen and oxygen com...

A Survey on Fog Computing and NB-IOT

The mobile network standard after Fourth Generation (4G) is Fifth Generation (5G) which is expected to provide internet connections at least 40 times faster than fourth generation. We can consider an example where user...

Download PDF file
  • EP ID EP19297
  • DOI -
  • Views 265
  • Downloads 6

How To Cite

Dr. -Ing. Momin E. Abdalla, (2015). Saturated Virial Coefficient of the Environmentally Friendly Refrigerant Fluids: R365mfc and R152a. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 3(1), -. https://europub.co.uk/articles/-A-19297