Abstract

ABSTRACT Fracture and loosening of the implant can pose a serious impact as the fractured segment remaining inside the implant may prevent it from functioning efficiently. The harmony between the implant supported prosthesis and implant could be disrupted, leading to failure of the upper structure. Fistula formation and soft tissue inflammation are frequently associated with loose abutment screws. This case report involved an evaluation of the screw threads of a loosened abutment compared with those of a fractured abutment removed from the same patient by Scanning Electron Microscopy (SEM). According to the results of the SEM analysis, deformities in the screw threads of the loosened abutment were evaluated, and whether a loosened abutment should be rescrewed was considered. In this case report an unused abutment screw, broken screw, and loosened abutment screw were analysed by SEM. In the loosened abutment screw, the thread was deformed in the concavities to a greater extent, than in the convexities. The metal structure appeared strained without any cracks. In the fractured abutment screw, the metal structure in the convexities appeared strained with small cracks present at grain boundaries. Crack growth appeared to be related to the high number of crack coalescence events. A significant difference was observed between screw threads with abutment loosening and screw threads without abutment loosening. Therefore, a loosened abutment should not be rescrewed because it increases the risk of abutment fracture.

Authors and Affiliations

Leblebicioglu Kurtulus Ikbal, Kuru Emel, Canakci Gulfesan

Keywords

Related Articles

Psychosis in a Case of Dandy-Walker Syndrome: A Case Report

Dandy Walker Syndrome (DWS) is a congenital malformation with brain abnormalities, intellectual disabilities, epilepsy and visible structural changes in particular brain structures. We present here a case of psychosis in...

Incidence of Metabolic Syndrome in Patients Admitted to Medical Wards with ST Elevation Myocardial Infarction

Introduction: Metabolic Syndrome (MS) consists of a cluster of metabolic abnormalities that confer exaggerated risk of cardiovascular disease. MS is a novel risk factor for Coronary Artery Disease (CAD) and is a rising d...

Relationship of Respiratory Muscle Strength and Walking Distance with Pulmonary Function, Quality of Life and Nitric Oxide in Chronic Obstructive Pulmonary Disease Patients

ABSTRACT Introduction: Respiratory muscle strength and walking distance have been associated with the severity of disease and is used in prescribing rehabilitation programs for persons with Chronic Obstructive Pulmonary...

Patient Centered Outcomes in Periodontal Treatment-An Evidenced Based Approach

Transformation of research into clinical practice is the most challenging step in evidence based dental practice. Designing the most reliable research with applicable endpoint evaluation is very important as it can lead...

Recovery Profile Using Modified Aldrete Score in Post Anaesthesia Care Unit After Sevoflurane or Desflurane Anaesthesia: A Prospective Randomised Study

ABSTRACT Introduction: General Anaesthesia should provide rapid smooth induction and optimal conditions during the perioperative period. It should also provide rapid recovery and minimum monitoring period to meet dischar...

Download PDF file
  • EP ID EP522640
  • DOI 10.7860/JCDR/2018/31092.11311
  • Views 58
  • Downloads 0

How To Cite

Leblebicioglu Kurtulus Ikbal, Kuru Emel, Canakci Gulfesan (2018). Scanning Electron Microscopic Analysis of the Screw Threads of Loosened and Fractured Abutments: A Case Report. Journal of Clinical and Diagnostic Research, 12(3), 4-6. https://europub.co.uk/articles/-A-522640