Screening Performance Characteristic of Ultrasonography and Radiog-raphy in Detection of Pleural Effusion; a Meta-Analysis

Journal Title: Archives of Academic Emergency Medicine - Year 2016, Vol 4, Issue 1

Abstract

Introduction: The role of ultrasonography in detection of pleural effusion has long been a subject of interest but controversial results have been reported. Accordingly, this study aims to conduct a systematic review of the available literature on diagnostic value of ultrasonography and radiography in detection of pleural effusion through a meta-analytic approach. Methods: An extended search was done in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Two reviewers independently extracted the data and assessed the quality of the articles. Meta-analysis was performed using a mixed-effects binary regression model. Finally, subgroup analysis was carried out in order to find the sources of heterogeneity between the included studies. Results: 12 studies were included in this meta-analysis (1554 subjects, 58.6% male). Pooled sensitivity of ultrasonography in detection of pleural effusion was 0.94 (95% CI: 0.88-0.97; I2= 84.23, p<0.001) and its pooled specificity was calculated to be 0.98 (95% CI: 0.92-1.0; I2= 88.65, p<0.001), while sensitivity and specificity of chest radiography were 0.51 (95% CI: 0.33-0.68; I2= 91.76, p<0.001) and 0.91 (95% CI: 0.68-0.98; I2= 92.86, p<0.001), respectively. Sensitivity of ultrasonography was found to be higher when the procedure was carried out by an intensivist or a radiologist using 5-10 MHz transducers. Conclusion: Chest ultrasonography, as a screening tool, has a higher diagnostic accuracy in identification of plural effusion compared to radiography. The sensitivity of this imaging modality was found to be higher when performed by a radiologist or an intensivist and using 5-10MHz probes.

Authors and Affiliations

Keywords

Related Articles

Point of Care Ultrasound in Detection of Brain Hemorrhage and Skull Fracture Following Pediatric Head Trauma; a Diagnostic Accuracy Study

Introduction: Head trauma is a common reason for emergency department visits worldwide; many of which involve young children. We sought to determine if head ultrasound (US), as a portable, fast and safe modality, can gui...

Dissimilarity in the Frequency of Venous Thromboembolism Risk Factors among Studies, a Commentary

Venous Thromboembolism (VTE) is the 3rd most prevalent vascular disease behind myocardial infarction and cerebrovascular ischemic attack (1). This disorder has received attention from health policy makers because of its...

Quality of Life in Emergency Medicine Specialists of Teaching Hospitals

Introduction: Quality of life (QOL) of emergency medicine specialists can be effective in providing services to patients. The aim of the present study was evaluating the lifestyle of emergency medicine practitioners, und...

Serum and cerebrospinal fluid levels of S-100B is a biomarker for spinal cord injury; a systematic review and meta-analysis

Introduction: There is controversy regarding the value of serum or cerebrospinal fluid (CSF) levels of S100 calcium-binding protein B (S-100B) in spinal cord injury (SCI). For reaching a general conclusion, the present m...

Comparison of Ultrasonography and Radiography in Detection of Thoracic Bone Fractures; a Systematic Review and Meta-Analysis

Introduction: The potential benefit of ultrasonography for detection of thoracic bone fractures has been proven in various surveys but no comprehensive conclusion has been drawn yet; therefore, the present study aimed to...

Download PDF file
  • EP ID EP330181
  • DOI -
  • Views 194
  • Downloads 0

How To Cite

(2016). Screening Performance Characteristic of Ultrasonography and Radiog-raphy in Detection of Pleural Effusion; a Meta-Analysis. Archives of Academic Emergency Medicine, 4(1), 1-10. https://europub.co.uk/articles/-A-330181