Seismic Analysis of Multi Storey RC Building with and Without Fluid Viscous Damper

Abstract

Earthquake is the important term that comes to mind while designing any multistory building. Earthquake is one of the most disastrous of natural criteria. Seismic waves are the main reason for development of vibration in the ground, impact of this will cause damage to the building. In this study G 12 storey building of rectangular plan is considered for the seismic analysis. The equivalent static method and response sectrum method is used for seismic evaluation of building with and without fluid viscous damper. ETABs 2017 software used for the analysis of the building, by considering seismic zone V and medium soil Type II as per IS 1893 2016. Storey displacement, storey shear, storey drift and modal periods and frequencies are considered for checking the performances of the building. Objective of this study is to compare results obtained from static and response spectrum analysis in both longitudinal and transverse direction for with and without damper building. Varun M | B S Sureshchandra "Seismic Analysis of Multi Storey RC Building with and Without Fluid Viscous Damper" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-4 | Issue-6 , October 2020, URL: https://www.ijtsrd.com/papers/ijtsrd33390.pdf Paper Url: https://www.ijtsrd.com/engineering/structural-engineering/33390/seismic-analysis-of-multi-storey-rc-building-with-and-without-fluid-viscous-damper/varun-m

Authors and Affiliations

Varun M

Keywords

Related Articles

Instructional Supervision by Principals An Appraisal from the Perspective of Teachers Job Performance in Some Selected Secondary Schools in Boyo Division

This study focused on performance of instructional supervision by principals in selected secondary schools in Boyo Division, North West Region. The objective was to investigate the impact of instructional supervision on...

Quantum Computing Pinning Down the Age of Universe

Hubble, The advance technology leads to many discoveries in Astronomy world. One of them is estimating the age of universe. This paper provides an Overview on how Hubble, its Scientific instruments, Communication Technol...

Arsenic Contamination of Ground water and Health Risk

The arsenic poisoning due to contaminated groundwater in West Bengal, India, and all of Bangladesh has been thought to be limited to the Ganges Delta despite early survey reports of arsenic contamination in groundwater i...

An Experimental Investigation on Concrete with Copper Slag using Corrosion Resistance Techniques

Now a days, the application of waste material usage in building materials has increased effectively. Copper slag is a by product created during the copper smelting and refining process. This material represents a popular...

The Education and Compensation Factors Affect to the Performance

The organization is the collection of people who cooperate in achieving the objectives which people have different behavior in work and needed a good education that should be owned by the Organization so that all employe...

Download PDF file
  • EP ID EP690598
  • DOI -
  • Views 118
  • Downloads 0

How To Cite

Varun M (2020). Seismic Analysis of Multi Storey RC Building with and Without Fluid Viscous Damper. International Journal of Trend in Scientific Research and Development, 4(6), -. https://europub.co.uk/articles/-A-690598