Abstract

Current research works and observations indicated that parts of the Kingdom of Saudi Arabia have low to moderate seismic regions. Major parts of buildings were designed only for gravity load and were poorly detailed to accommodate lateral loads. This study aims to investigate building performance on resisting expected seismic loadings. Two 3D frames were investigated using pushover analysis according to ATC-40. One was designed according to a design practice that considers only the gravity load and the other frame was designed according to the Saudi Building Code (SBC-301). Results showed that the building designed considering only the gravity load was found inadequate. On the other hand, the building designed according to SBC-301 satisfies the Immediate Occupancy (IO) acceptance criteria according to ATC-40.

Authors and Affiliations

R. A. Hakim, M. S. Alama, S. A. Ashour

Keywords

Related Articles

Numerical and Experimental Efficiency Evaluation of a Counter-Rotating Vertical Axis Wind Turbine

This paper investigates the concept of a concentric counter-rotating vertical axis wind turbine (VAWT), consisting of a two stage vertical H-type turbine with three blades on each stage. The model has an inner and an out...

Assessment of the Suitability of Paper Waste as an Engineering Material

This research work investigates the potential applicability of waste paper in the production of ceiling boards with focus on achieving: environmental sustainability, safe disposal of waste paper and more cost effective p...

An MTSS Based Underground Coal Mining Simulation Model

In the frames of simulation system, a specialized library of simulating models of mining equipment and coal seam (MTSS) was implemented. Using the specialized simulating model library of technological mining equipment an...

Machining and Surface Characteristics of AISI 304L After Electric Discharge Machining for Copper and Graphite Electrodes in Different Dielectric Liquids

In Electric Discharge Machining (EDM), the thermal energy used for material erosion depends on the intensity of electric sparks, the thermal conductivities of electrode material and the dielectric liquid. In this paper,...

Analysis of Retransmission Policies for Parallel Data Transmission

Stream control transmission protocol (SCTP) is a transport layer protocol, which is efficient, reliable, and connection-oriented as compared to transmission control protocol (TCP) and user datagram protocol (UDP). Additi...

Download PDF file
  • EP ID EP91040
  • DOI -
  • Views 285
  • Downloads 0

How To Cite

R. A. Hakim, M. S. Alama, S. A. Ashour (2014). Seismic Assessment of an RC Building Using Pushover Analysis. Engineering, Technology & Applied Science Research, 4(3), -. https://europub.co.uk/articles/-A-91040