Seismic Assessment of an RC Building Using Pushover Analysis

Journal Title: Engineering, Technology & Applied Science Research - Year 2014, Vol 4, Issue 3

Abstract

Current research works and observations indicated that parts of the Kingdom of Saudi Arabia have low to moderate seismic regions. Major parts of buildings were designed only for gravity load and were poorly detailed to accommodate lateral loads. This study aims to investigate building performance on resisting expected seismic loadings. Two 3D frames were investigated using pushover analysis according to ATC-40. One was designed according to a design practice that considers only the gravity load and the other frame was designed according to the Saudi Building Code (SBC-301). Results showed that the building designed considering only the gravity load was found inadequate. On the other hand, the building designed according to SBC-301 satisfies the Immediate Occupancy (IO) acceptance criteria according to ATC-40.

Authors and Affiliations

R. A. Hakim, M. S. Alama, S. A. Ashour

Keywords

Related Articles

Analysis of Video Signal Transmission Through DWDM Network Based on a Quality Check Algorithm

This paper provides an analysis of the multiplexed video signal transmission through the Dense Wavelength Division Multiplexing (DWDM) network based on a quality check algorithm, which determines where the interruption o...

Cloud Masking for Remotely Sensed Data Using Spectral and Principal Components Analysis

Two methods of cloud masking tuned to tropical conditions have been developed, based on spectral analysis and Principal Components Analysis (PCA) of Moderate Resolution Imaging Spectroradiometer (MODIS) data. In the spec...

Performance Analysis of OFDM and OFDM-MIMO Systems under Fading Channels

Fourth-generation (4G) wireless communication system is mainly based on MIMO (multiple input and multiple output) and OFDM (orthogonal frequency division multiplexing). The combination of these two techniques leads to a...

Effect of Iron Additives on the Microstructure of Hydroxyapatite

In this article, some Fe (III) doped hydroxyapatite samples (FeHAp) were prepared using the wet chemical method. The prepared samples were characterized via the use of X-ray diffraction (XRD) and scanning electron micros...

A Study of SiR/EPDM Mixtures for Outdoor Insulators

This paper deals with the flashover voltages on samples of silicone rubber/ethylene propylene diene monomer (SiR/EPDM) mixtures under the influence of a uniform electric field. Five different mixtures of SiR/EPDM were in...

Download PDF file
  • EP ID EP91040
  • DOI -
  • Views 240
  • Downloads 0

How To Cite

R. A. Hakim, M. S. Alama, S. A. Ashour (2014). Seismic Assessment of an RC Building Using Pushover Analysis. Engineering, Technology & Applied Science Research, 4(3), -. https://europub.co.uk/articles/-A-91040