Abstract

Current research works and observations indicated that parts of the Kingdom of Saudi Arabia have low to moderate seismic regions. Major parts of buildings were designed only for gravity load and were poorly detailed to accommodate lateral loads. This study aims to investigate building performance on resisting expected seismic loadings. Two 3D frames were investigated using pushover analysis according to ATC-40. One was designed according to a design practice that considers only the gravity load and the other frame was designed according to the Saudi Building Code (SBC-301). Results showed that the building designed considering only the gravity load was found inadequate. On the other hand, the building designed according to SBC-301 satisfies the Immediate Occupancy (IO) acceptance criteria according to ATC-40.

Authors and Affiliations

R. A. Hakim, M. S. Alama, S. A. Ashour

Keywords

Related Articles

Performance Analysis of Non-Isolated DC-DC Buck Converter Using Resonant Approach

DC-DC converters preserve or control the output DC voltage. Due to parasitic constituents such as leakage capacitance of both diode and inductor, and transformer leakage inductance, DC-DC converters mostly operate on rig...

Application of Fuzzy Expert Systems to Manage the Projects Time in Iranian Gas Refineries

The National Iranian Gas Company (NIGC) is one of the top ten gas companies in the gas industry in the Middle East and is comprised of 7 gas refineries. So this company needs to apply the most optimum time management met...

Behaviour of Water Droplets Under the Influence of a Uniform Electric Field in Nanocomposite Samples of Epoxy Resin/TiO2

In this paper nanocomposite samples of epoxy resin and TiO2 nanoparticles were investigated with water droplets on their surface. A uniform electric field was applied and the behaviour of the water droplets was observed....

Application of using Hybrid Renewable Energy in Saudi Arabia

One of the major world wide concerns of the utilities is to reduce the emissions from traditional power plants by using renewable energy and to reduce the high cost of supplying electricity to remote areas. Hybrid power...

Performance of Geosynthetic-Reinforced Soils Under Static and Cyclic Loading

This paper investigates and discusses the composite behavior of geosynthetic reinforced soil mass. It presents the results of a series of large-scale laboratory tests supported by analytical methods to examine the perfor...

Download PDF file
  • EP ID EP91040
  • DOI -
  • Views 263
  • Downloads 0

How To Cite

R. A. Hakim, M. S. Alama, S. A. Ashour (2014). Seismic Assessment of an RC Building Using Pushover Analysis. Engineering, Technology & Applied Science Research, 4(3), -. https://europub.co.uk/articles/-A-91040